Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI

UPS

The UTS is equipped with a standard IEC 320, 120 V inlet specifically intended for use with a UPS. Use the power cord

supplied in the accessories kit to connect the UPS to the UTS.
The UTS is equipped with a standard NEMA 5-15, 120 V Convenience outlet for connecting a UPS or another selected

load to the UTS. The Convenience outlet can utilize utility power or generator power, providing an uninterruptible power

supply during a power outage or fluctuation.
If any circuits are to be configured as uninterruptible, a UPS must be used as the Backup2 power source. The UPS input

cord should plug into the convenience outlet to allow the UPS battery to charge while operating on generator power.
For details on UPS installation and specifications refer to the UPS documentation.

Other backup power sources

The UTS can utilize backup power sources other than a generator and a UPS. Contact APC at www.apc.com for

information on alternative backup power sources.