beautypg.com

Step 3: thermostat location and strapping layout – King Electric FCM Floor Mat User Manual

Page 9

background image

STEP 3: Thermostat location and strapping layout

(continued)

King Electrical Floor Heating Mat Installation Manual

9

Product Selection Chart

120V

Heated Area

Mat Dimensions

Watts

(12W/sq.ft.)

Amps

ohms

Catalog

Number

sq.ft.

m

2

in.*ft.

m*m

FCM1-10

10

0.93

30*4

0.76*1.2

120

1

120

FCM1-15

15

1.39

30*6

0.76*1.8

180

1.5

80

FCM1-20

20

1.86

30*8

0.76*2.4

240

2

60

FCM1-25

25

2.32

30*10

0.76*3.1

300

2.5

48

FCM1-30

30

2.79

30*12

0.76*3.7

360

3

40

FCM1-35

35

3.25

30*14

0.76*4.3

420

3.5

34.3

FCM1-40

40

3.72

30*16

0.76*4.9

480

4

30

FCM1-50

50

4.65

30*20

0.76*6.1

600

5

24

FCM1-60

60

5.57

30*24

0.76*7.3

720

6

20

FCM1-70

70

6.5

30*28

0.76*8.6

840

7

17.1

FCM1-80

80

7.43

30*32

0.76*9.8

960

8

15

FCM1-90

90

8.36

30*36

0.76*11.0

1080

9

13.3

FCM1-100

100

9.29

30*40

0.76*12.2

1200

10

12


240V

Heated Area

Mat Dimensions

Watts

(12W/sq.ft.)

Amps

ohms

Catalog

Number

sq.ft.

m

2

in.*ft.

m*m

FCM2-20

20

1.86

30*8

0.76*2.4

240

1

240

FCM2-30

30

2.79

30*12

0.76*3.7

360

1.5

160

FCM2-35

35

3.25

30*14

0.76*4.3

420

1.8

137.1

FCM2-40

40

3.72

30*16

0.76*4.9

480

2

120

FCM2-50

50

4.65

30*20

0.76*6.1

600

2.5

96

FCM2-60

60

5.57

30*24

0.76*7.3

720

3

80

FCM2-70

70

6.5

30*28

0.76*8.6

840

3.5

68.6

FCM2-80

80

7.43

30*32

0.76*9.8

960

4

60

FCM2-90

90

8.36

30*36

0.76*11.0

1080

4.5

53.3

FCM2-100

100

9.29

30*40

0.76*12.2

1200

5

48

FCM2-110

110

10.22

30*44

0.76*13.4

1320

5.5

43.6

FCM2-120

120

11.15

30*48

0.76*14.7

1440

6

40

FCM2-145

145

13.47

30*58

0.76*17.7

1740

7.3

33.1

FCM2-160

160

14.86

30*64

0.76*19.6

1920

8

30

* 240 volt cables are approved for 208 volt, but will produce 25% less wattage.

120V Models

240V Models