Voltage Input Signal

Warning! Read Safety Warning on Page 1
before attempting to use this control.

Note: The Voltage/Current (VLT/CUR) jumper must be in the VLT position (factory setting).
The KBSI-240D is designed to accept a wide range of input voltage signals as follows:

Connect input voltage signal to proper input terminals as
indicated in figure 4.

1.

Connect a 10V DC meter (digital meter is suggested)
to terminals “9” (-) and “10” (+).

2.

Apply the maximum input voltage that would be supplied from tach, transducer, etc.

3.

Adjust the “MAX” trimpot to the desired output voltage.

Example: A follower motor is to follow the output of a main motor with an armature volt-
age range of 0 - 90V.

7

Minimum Input
Voltage Range

Input Terminals

5, 6

Maximum Input

Voltage Range

0 - 5

0 - 25

5, 7

0 - 25

0 - 120

5, 8

0 - 120

0 - 550

TABLE 2 – VOLTAGE INPUT SIGNAL

5

6

+

+

+

7

8

0 - 550V

0 - 120V

0 - 25V

FIGURE 4 – VOLTAGE INPUT

SIGNAL CONNECTIONS

!