KB Electronics KBSI-240D KBSI Signal Isolator User Manual
Page 13
Note: The preceding circuit provides for the speed pot to be used in “MAN” mode only. In “AUT0”
mode, the process control signal is supplied directly to the signal isolator.
11
Motor
A(-)
F(-)
A(+)
P3
Auto
W/Ratio
Manual
5K Pot
10(+)
9(-)
P2
KB
CONTROL
KBSI-240D
The following circuit
provides for dual pur-
pose usage of the
speed pot. In the
“AUTO” mode it is
used for ratio control
and in the “MAN”
mode it is used for
manual speed adjust-
ment.
FIGURE 6C – PROCESS CONTROL WITH AUTO (RATIO POT)/MANUAL SWITCH
Motor
F(-)
P2
A(-)
A(+)
9(-)
10(+)
5
6
P1
Auto/Man
5K Pot
KB
CONTROL
Process
Signal
0 - 10V DC
KBSI-240D
FIGURE 6D – AUTO/MANUAL OPERATION WITH POTENTIOMETER ON KBSI INPUT
See also other documents in the category KB Electronics Software:
- KBVF-13 (45 pages)
- KBVF-27 (29 pages)
- KBDF-13 (73 pages)
- KBMA-24D (25 pages)
- KBWA-22D (36 pages)
- KBMK-24D (53 pages)
- KBDA-24D (57 pages)
- KBDA-29 (1P) (57 pages)
- KBDA-24P (57 pages)
- KBAC-24D (28 pages)
- KBAC-29 (1P) (29 pages)
- SIVFR (28 pages)
- DBM Dynamic Braking Module for Single Phase Input Models (4 pages)
- Power On/Off Switch Kit (2 pages)
- IODA, Input/Output Module for use with all KBDA/KBMK Controls (44 pages)
- SIAC, Signal Isolator, installs inside all KBAC Controls (6 pages)
- KBAC/KBDA -24D Power On/Off Switch Kit (1 page)
- KBAC/KBDA-27D Power On/Off Switch Kit (1 page)
- RFAC-24D CE Approved AC Line Filter, installs inside KBAC/KBDA-24D(Class A) (1 page)
- Fittings (KBAC/KBDA Liquid Tight Fittings, 3 x 0.5, 1 x 0.75")" (1 page)
- KBRF-200A CE Approved AC Line Filter for SCR Controls (Class A) (4 pages)
- KBRF-300 CE Approved AC Line Filter (Class B) (8 pages)
- KBTC-125 (1 page)
- KBIC-120 (28 pages)
- KBMM-125 (32 pages)
- KBWD-15 (9 pages)
- KBWS-12 (25 pages)
- KBCC-240D (22 pages)
- KBWT-16 (7 pages)
- KBMG-212D (36 pages)
- KBRG-212D (32 pages)
- KBRG-255 (18 pages)
- KBWM-120 (16 pages)
- KBPC-225D (19 pages)
- KBPI-240D (24 pages)
- KBPW-240D (19 pages)
- KBRC-240D (24 pages)
- KBBC-24M (5 pages)
- Multi Speed Board (16 pages)
- Anti Plug Reversing Module (APRM-PC) w/Switch Kit (for Model 240D Only) (14 pages)