B. local installation regulation, C. chemical vapor corrosion – HTP PHE199-119S User Manual
Page 6
6
LP- 204 REV. 3.25.14
Install all system components and piping in such a way that does not reduce the performance of any fire rated assembly. Failure to do
so may lead to fire, property damage, personal injury, or death.
Be sure to disconnect electrical power from the solar water heating system before performing service. Failure to do so could result in an
electrical shock, property damage, serious personal injury, or death.
Improper installation or use may result in property damage. Such damage IS NOT covered by warranty.
NOTE: HTP DOES NOT WARRANT THIS WATER HEATER AGAINST FREEZE RELATED DAMAGE.
ALL PIPING AND PLUMBING CONNECTIONS IN CLOSED LOOP SYSTEMS SHOULD BE MADE WITH COPPER PIPE ONLY. No
less than ¾” I.D. copper tube of the type meeting local codes must be used for piping. Pipe runs must be solidly attached with proper
clamping methods. Soldered connections should be secured with 95/5 lead-free solder. Use only pipe rated for 250
o
F minimum on both
the collector return and supply piping.
Only use this solar hot water system as intended and described in this installation manual. Any use other than described will void
warranty and may lead to fire, property damage, personal injury, or death.
High heat sources (sources generating heat 100
o
F / 37
o
C or greater, such as stove pipes, space heaters, etc.) may damage plastic
components of the water heater as well as plastic vent pipe materials. Such damages ARE NOT covered by warranty. It is
recommended to keep a minimum clearance of 8” from high heat sources. Observe heat source manufacturer instructions, as well as
local, state, provincial, and national codes, laws, regulations and ordinances when installing this water heater and related components
near high heat sources.
B. LOCAL INSTALLATION REGULATION
Installation of this solar water heater may be governed by individual local rules and regulations for this type of product, which must be
observed. Always use the latest edition of codes. The installation, adjustment, service, and maintenance of the solar water heater must
be done by a licensed professional who is qualified and experienced in the installation, service, and maintenance of solar hot water
systems.
C. CHEMICAL VAPOR CORROSION
NOTE: DAMAGE TO THE SOLAR WATER TANK, COLLECTOR, OR RELATED COMPONENTS CAUSED BY EXPOSURE TO
CORROSIVE VAPORS IS NOT COVERED BY WARRANTY. The warranty is voided if failure of water tank is due to a corrosive
atmosphere. (Refer to the limited warranty for complete terms and conditions).
PRODUCTS TO AVOID
AREAS LIKELY TO HAVE CONTAMINANTS
Spray cans containing fluorocarbons
Dry cleaning/laundry areas and establishments
Permanent wave solutions
Swimming pools
Chlorinated waxes/cleaners
Metal fabrication plants
Chlorine-based swimming pool chemicals
Beauty shops
Calcium chloride used for thawing
Refrigeration repair shops
Sodium chloride used for water softening
Photo processing plants
Refrigerant leaks
Auto body shops
Paint or varnish removers
Plastic manufacturing plants
Hydrochloric or Muriatic acid
Furniture refinishing areas and establishments
Cements and glues
New building construction
Antistatic fabric softeners used in clothes dryers
Remodeling areas
Chlorine-type bleaches, laundry detergents, and cleaning solvents
Garages and workshops
Adhesives used to fasten building products
Table 1
– Chemical Contaminants