26

LP- 204 REV. 3.25.14

NATURE OF TROUBLE

POSSIBLE CAUSE

SERVICE

No hot water

1. Improper wiring

Rewire per Wiring Diagram

2. No power

– blown fuse or circuit breaker

tripped
a. Shorted wiring
b. Circuit overloaded
c. Improper wiring

a. Repair
b. Provide adequate circuit or reduce load
c. Rewire

3. Solar system incorrectly installed

Check installation

4. Leaking plumbing or open hot water
faucet(s)

Make sure all faucet(s) are closed and check water
meter

Not enough hot water

1. Heater undersized

Reduce rate of hot water use

2. Wired incorrectly

Check wiring or replace

3. Solar system incorrectly installed

Check installation

Water too hot or not hot
enough

1. Setting too high or low

Change setting as required

2. Solar system incorrectly installed

Check installation

Table 3

See water heater installation manuals for more detailed maintenance information.

PART 11 - SYSTEM PARTS LISTING

A. ESTIMATED COMPONENT LIFE

When installed and maintained as directed by this manual, one can expect many years of trouble-free service from this solar system.
However, all components in this system are subject to installation conditions. For example: Where hard water is present, mineral
deposits can shorten the life of components. Periodic maintenance as prescribed by this manual ensures that these components are
well protected from such damage.

B. WARRANTIES AND DISCLAIMERS

NOTE: WE EXCLUDE ANY WARRANTY FOR, OR LIABILITY FROM ACTS OF NATURE, INCLUDING FREEZE DAMAGE.

Warranty periods for tank components are listed in the table below:

MANUFACTURER

ITEM

PART#

COMPONENT

COVERAGE

TANK

COVERAGE

HTP

Stainless Steel Solar Water Heater

w/ Gas-Fired Back-Up

PH130-80S

1 year

Residential

– 7 years

Commercial

– 3 years

HTP

Stainless Steel Solar Water Heater

w/ Gas-Fired Back-Up

PH130-119S

1 year

Residential

– 7 years

Commercial

– 3 years

HTP

Stainless Steel Solar Water Heater

w/ Gas-Fired Back-Up

PH199-80S

1 year

Residential

– 7 years

Commercial

– 3 years

HTP

Stainless Steel Solar Water Heater

w/ Gas-Fired Back-Up

PH199-119S

1 year

Residential

– 7 years

Commercial

– 3 years

HTP

Stainless Steel Solar Water Heater

w/ Gas-Fired Back-Up

PHE130-80S

1 year

Residential

– 12 years

Commercial

– 5 years

HTP

Stainless Steel Solar Water Heater

w/ Gas-Fired Back-Up

PHE130-119S

1 year

Residential

– 12 years

Commercial

– 5 years

HTP

Stainless Steel Solar Water Heater

w/ Gas-Fired Back-Up

PHE199-80S

1 year

Residential

– 12 years

Commercial

– 5 years

HTP

Stainless Steel Solar Water Heater

w/ Gas-Fired Back-Up

PHE199-119S

1 year

Residential

– 12 years

Commercial

– 5 years

Table 4