Gilderfluke&Co PA System User Manual
Page 37

- 'Digital Data to Repeaters' -
- 26 Pin IDS Connector -
- DIGITAL Signals FROM MA-100 to CC-400 / CC-1600 Card Cages -
Pin #
Signal Function
Connects to J1 Pin #
1
Reserved
1A
2
n/c
1B
3
Reserved
1C
4
- Repeater Tx Data
2A
5
n/c
2B
6
+ Repeater Tx Data
2C
7
- Repeater Rx Data
3A
8
n/c
3B
9
+ Repeater Rx Data
3C
10
n/c
4A
11
n/c
4B
12
n/c
4C
13
n/c
5A
14
n/c
5B
15
n/c
5C
16
n/c
6A
17
n/c
6B
18
n/c
6C
19
n/c
7A
20
n/c
7B
21
n/c
7C
22
n/c
8B
23
n/c
9B
24
n/c
n/c
25
Ground
15A, 15B, 15C
26
n/c
n/c
- 'Analog Output' -
- 20 Pin IDS (1/2 J-6A) -
- Used to link VCA Buss between MA-100 and Card Cages -
Pin #
Signal Function
Connects to J1 Pin #
1
n/c
2
n/c
3
Ground
15A, 15B, 15C
4
VCA Buss #8
25B
5
Ground
15A, 15B, 15C
6
VCA Buss #7
25A
7
Ground
15A, 15B, 15C
8
VCA Buss #6
24C
9
Ground
15A, 15B, 15C
10
VCA Buss #5
24B
11
n/c
12
n/c
13
Ground
15A, 15B, 15C
14
VCA Buss #4
24A
15
Ground
15A, 15B, 15C
16
VCA Buss #3
23C
17
Ground
15A, 15B, 15C
18
VCA Buss #2
23B
19
Ground
15A, 15B, 15C
20
VCA Buss #1
23A
G
ILDERFLUKE
& C
O
. ¥ 205 S
OUTH
F
LOWER
S
T
. ¥ B
URBANK
, C
ALIF
. 91502-2102 ¥ 818/840-9484 ¥
FAX
818/840-9485