Printer Port Connections and Communications:
The Intelligent PA System supports a single ÔPRINTER OutputÕ port. This can be attached to a printer or
CRT to log selected PA System activity. Connections to this serial port are similar to those used for the
TERMINAL Input port, except that instead of a data input line the printer port supports only a handshaking
line.
The Printer Output is also 6 position RJ-11 (modular telephone style connector). Facing the end of
the cable with the release latch upwards, its pin out is as follows:
COLOR
Signal NAME:
LEFT
White
Signal Ground
Black
- Serial Data OUT FROM PA SYSTEM
Red
+ Serial Data OUT FROM PA SYSTEM
Green
- Clear to Send IN to PA SYSTEM
Yellow
+ Clear to Send IN to PA SYSTEM
RIGHT
Blue
Signal Ground
The printer port is set for 9600 baud, 8 bits of data, 1 stop bit, no parity.