INTELLIGENT PA SYSTEM HARDWARE CONFIGURATION:
Each MA-200, including the one inside the MA-100, must be addressed before it is connected and
turned on. A 5 position dipswitch or a rotary switch (plus a 2 position dipswitch) on the back of each unit
is used to set which address the PA stations and Local Outputs on each MA-200 will respond to. With up
to 32 MA-200Õs attached to the system, the following are all of the possible settings for these switches:
MA-100
PA Station
or
and
MA-200
5
4
3
2
1
Rotary Sw
1
MA-100/200 Outputs
1
on
on
on
on
on
0
00 through 07
2
on
on
on
on
open
0
08 through 0F
3
on
on
on
open
on
1
10 through 17
4
on
on
on
open
open
1
18 through 1F
5
on
on
open
on
on
2
20 through 27
6
on
on
open
on
open
2
28 through 2F
7
on
on
open
open
on
3
30 through 37
8
on
on
open
open
open
3
38 through 3F
9
on
open
on
on
on
4
40 through 47
10
on
open
on
on
open
4
48 through 4F
11
on
open
on
open
on
5
50 through 57
12
on
open
on
open
open
5
58 through 5F
13
on
open
open
on
on
6
60 through 67
14
on
open
open
on
open
6
68 through 6F
15
on
open
open
open
on
7
70 through 77
16
on
open
open
open
open
7
78 through 7F
17
open
on
on
on
on
8
80 through 87
18
open
on
on
on
open
8
88 through 8F
19
open
on
on
open
on
9
90 through 97
20
open
on
on
open
open
9
98 through 9F
21
open
on
open
on
on
A
A0 through A7
22
open
on
open
on
open
A
A8 through AF
23
open
on
open
open
on
B
B0 through B7
24
open
on
open
open
open
B
B8 through BF
25
open
open
on
on
on
C
C0 through C7
26
open
open
on
on
open
C
C8 through CF
27
open
open
on
open
on
D
D0 through D7
28
open
open
on
open
open
D
D8 through DF
29
open
open
open
on
on
E
E0 through E7
30
open
open
open
on
open
E
E8 through EF
31
open
open
open
open
on
F
F0 through F7
32
open
open
open
open
open
F
F8 through FF
The ÔOPENÕ position on each switch is towards the top of the case.
The MA-100 is usually addressed as #1, but can be set for any address desired so long as it doesnÕt
conflict with any MA-200.
The four serial ports on the MA-100 can each be configured to different baud rates using wire wrap
G
ILDERFLUKE
& C
O
. ¥ 205 S
OUTH
F
LOWER
S
T
. ¥ B
URBANK
, C
ALIF
. 91502-2102 ¥ 818/840-9484 ¥
FAX
818/840-9485
8 of 35
1
With the MA-100/200s with the address set with a rotary switch, the #2 dipswitch is set as shown for
the #1 switch column.