Configuration Screen:
The menu will appear as follows. Decimal values have been selected for the numbers. At the top of
the screen the size of the Animation Data Eprom installed (if any) is shown. If the Animation Data Eprom
isn't found, then 'not found' will appear in this space.
-Gilderfluke & Company - DMX-512 MultiShow Brick - ver1.02 - copyright 1999 DCM-
All memory writes are disabled. You can not alter the current configuration.
Eprom: 123 shows with 123 channels @ 123 Offset / Set FileName is FUDDNUTS
a) serial address- __0 | c) DMX Rx checksums- yes
b) numbering system- decimal | d) VT-52 display- yes
0) input 0: close loops shows __1 on a_______ | open not used
1) input 1: close loops shows __2 on _b______ | open not used
2) input 2: close loops shows __3 on __c_____ | open not used
3) input 3: close loops shows __4 on ___d____ | open not used
4) input 4: close loops shows __5 on ____e___ | open not used
5) input 5: close loops shows __6 on _____f__ | open not used
6) input 6: close loops shows __7 on ______g_ | open not used
7) input 7: close loops shows __8 on _______h | open not used
8) green : close E-stops shows on abcdefgh | open clears E-stops on abcdefgh
9) blue : close pauses shows on abcdefgh | open continues shows on abcdefgh
sequencer numbers: a b c d e f g h
e) PowerOn/E-Stops go to show #|___1_|___2_|___3_|___4_|___5_|___6_|___7_|___8_|
f) Ease-In speed (in seconds): |_2.1_|_2.1_|_2.1_|_2.1_|_2.1_|_2.1_|_2.1_|_2.1_|
g) EaseIn Chans. | i) info | o) load defs. | p) play | r) save Config. | x) eXit
Enter Command-
All numeric values are entered in HEXadecimal (0-9, A through F) or Decimal numbers (0-9), as select-
ed on the menu. Each number consist of one or more ASCII characters followed by a
(
lowed, then the characters already entered will scroll to the left to make room for the new entries. Once a
command has been invoked, characters can be erased one-by-one by using the
(
mand can be canceled altogether by hitting the
Once you have configured a BR-MultiShow, you should ÔlockÕ the configuration by moving the ÔWrite
ProtectÕ jumper to the ÔWrite ProtectÕ position from the ÔEnabledÕ position. This should protect your configu-
ration from anything shy of a lightning hit. As shown above, the second line of the menu will change to
show that the Eprom has been protected and warn you that you can no longer make any changes.
Configuration changes can be re-enabled at any time by moving the jumper back to the ÔEnabledÕ posi-
tion.
If you want to keep a hard copy printout of the current configuration of the BR-MultiShow: Press the
puter. This file can then be printed out at any time.
a) Serial Port Address: This command is used to set the address that this card will be respond to
on the RS-422 Serial port. Only one card at a time can use each address. This means that if
you are configuring several cards, you may need to plug each one in one at a time and set
each of them to unique addresses. After they are addressed, you can plug them all in at the
same time and talk to them freely.
b) Numbering System: This toggle is used to select between HEXadecimal or Decimal numbering
systems for display and entries. When percentage is selected, all entries are still made in
Decimal numbers.
c) DMX Rx Checksum: This toggle is used to enable and disable the error checking in data re-
G
ILDERFLUKE
& C
O
.¥ 205 S. F
LOWER
S
T
. ¥ B
URBANK
, CA 91502 ¥ 818/840-9484 ¥ 800/776-5972 ¥
FAX
818/840-9485
12 of 22