beautypg.com

Initial setup, Adding vacuum pump oil – Robinair 34134Z Refrigerant Recovery, Recycle, Recharge Unit User Manual

Page 9

background image

Recover/Recycle/Recharge Unit

7

After registering the unit, use the following steps to add oil to the vacuum
pump.

IMPORTANT: For maximum unit performance, change the vacuum pump
oil after every 10 hours of operation. (The unit will prompt a vacuum
pump oil change after every 10 hours of operation.

1. Plug the unit’s power cord into a correct voltage outlet.

Initial Setup

Oil Filler Cap and Tube
(included in accessory kit)

INST1003

Vacuum Pump

2. Remove the plastic plug from the oil fill port.

3. Attach the oil filler cap and tube to a vacuum pump oil bottle, and pour about

6 ounces (175 mL) of oil into the oil fill port.

4. Turn the unit’s power switch on.

5. On the control panel, verify both panel valves are open, and verify the

service couplers are disconnected from the vehicle. Screen will display:

6. Press Start/Stop key to start the vacuum pump.

CLEAR 02.00

IMPORTANT!

The vacuum
pump is shipped
without oil in the
reservoir. To
avoid pump
damage, add oil
before starting
the pump.

Adding Vacuum Pump Oil

CAUTION!

Avoid using an
extension cord.
An extension
cord may
overheat and
cause fire. If you
must use an
extension cord,
use the shortest
possible cord
with a minimum
size of 14 AWG.

Oil Sight Glass

Oil Fill Port