1. Connect the low-side tank adapter (from the accessory kit) to the liquid
valve on the refrigerant source tank.
NOTE: If using a refillable source tank,
connect the tank adapter to the vapor valve.
R-134a Tank Adapter
2. Connect the service coupler of the low-side hose (blue) to the refrigerant
source tank.
3. Open the valve on the source tank, and place the tank upside down in the
source tank compartment. Secure the source tank in place by wrapping the
strap around the tank, and then fastening the strap.
4. The screen should display RECOVER XX.XXLBS. If it does not, scroll
through the functions by pressing the Mode key until RECOVER XX.XXLBS
is displayed.
5. Press the Arrow keys to adjust the recover weight to 15 lbs. (7 kg).
6. On the control panel, open the low-side valve; verify the high-side valve is
closed.