Initial setup, Warning – Robinair 34134Z Refrigerant Recovery, Recycle, Recharge Unit User Manual
Page 14
©
2003 SPX Corporation
12
Initial Setup
Changing the Temperature Scale (Fahrenheit or Celsius)
The temperature scale is set to Fahrenheit at the factory. Use the following
steps to toggle the temperature scale to Celsius.
1. Disconnect the unit’s power cord from the outlet.
High voltage electricity inside the unit has a risk of electrical
shock. Disconnect the power before servicing the unit.
2. Remove the four screws that secure the top section of the unit’s protective
covering and remove the covering.
3. Locate the selector switch on the back of the tank temperature display.
4. Change the position of the switch to change the temperature scale.
5. Replace the top section of the unit’s protective covering, and replace the
four screws that secure the covering.
WARNING
INST1005
Selector
Switch
Control Panel — Inside, Back View