Operating guidelines – Robinair 178012K Recovery, Recycling, Recharging Unit User Manual
Page 32
© 2000 Robinair, SPX Corporation
30
Segment A — Indicates in which mode the unit is operating:
PROGRAM — The unit is in the programming mode, which allows you to pro-
gram vacuum time and refrigerant weight or to review the existing program.
HOLD — This mode is used to change a refrigerant tank or to interrupt the
vacuum/charging/recovery cycles.
AUTOMATIC — Indicates that the unit is running in a given cycle and will auto-
matically stop when the cycle is complete. One exception: the recycling process
must be stopped by pressing HOLD/CONT.
Segment B — Indicates that the unit is either evacuating the A/C-R system or recover-
ing, recycling, or recharging refrigerant or that the unit is ready to be programmed for
one of the following functions (Use the chart on the next page as a quick reference for
interpreting Segment B messages).
VACUUM
•
With PROGRAM, indicates that the unit is ready to be programmed for vacuum.
•
With AUTOMATIC, indicates that the vacuum pump is running; the number
displayed counts down in minutes and seconds, showing the amount of time remain-
ing.
•
With HOLD, indicates that HOLD/CONT was pressed to interrupt the vacuum
cycle.
RECYCLE
•
With AUTOMATIC, indicates the unit is recycling refrigerant from the tank.
CHARGE
•
With PROGRAM, indicates that the unit is ready to be programmed for the amount
of refrigerant to be charged into the A/C-R system; on the keypad enter the charge
in pounds and hundredths of a pound or kilograms, depending on the measurement
mode selected.
•
With AUTOMATIC, indicates the unit is charging refrigerant into the A/C-R
system; the number shown on the digital display counts down, showing the remain-
ing amount of refrigerant to be dispensed.
Operating Guidelines