beautypg.com

Operation, Archive, Opera – Ransburg RF1 FiberOptic Meter 77786-XX, A11516-XX User Manual

Page 22: Opera operation tion tion tion tion

background image

FM-00-02.5

GENERAL

GENERAL

GENERAL

GENERAL

GENERAL OPERA

OPERA

OPERA

OPERA

OPERATION

TION

TION

TION

TION

To operate the unit, connect the unit in place per
installation instructions. Allow paint to flow through
the meter. Read results through appropriate
display.

CALIBRA

CALIBRA

CALIBRA

CALIBRA

CALIBRATION

TION

TION

TION

TION

Refer to appropriate associated equipment for
calibration procedure.

FLOW METER

FLOW METER

FLOW METER

FLOW METER

FLOW METER

SERVICING

SERVICING

SERVICING

SERVICING

SERVICING

Flow meter problems can be caused by improperly
filtered fluid. Particulates in the fluid can cause
gear binding, resulting in improper signals for the
actual flow rate. Maintain the fluid filters according
to the instructions from the filter manufacturer. If
repeated disassembly and cleaning for removal of
solids and particulates occurs, inspect the entire
fluid supply system and evaluate the system
cleaning cycle.

Fluid back-up, that is reverse flow of 2k
components, can cause reacted/catalyzed
material to enter the flow meter. Reverse flow
must be detected by the 2k controls and the
system must shut down. The flow meter should be
cleaned immediately, before the fluid sets-up.

SERVICE

SERVICE

SERVICE

SERVICE

SERVICE

1. Disconnect fiber optic cable [13] from trans-
mitter [1]. Remove meter to a suitable area to
perform maintenance.

1 8

1 8

1 8

1 8

1 8

RF 1 Fiber Optic - Operation

2. Remove three (3) Phillips head screws from
transmitter [1]. Remove cover plate. Remove two
(2) #8 - 32 x 1” socket head cap screws. Remove
transmitter [1] from the flow meter body.

3. Using a 3/16” Allen wrench, remove all the
bolts. Pull the sensor section STRAIGHT apart
from the gear pocket section. Pull the gears and
pins from the gear pocket section. Clean and
replace worn parts as necessary.

4. Install new Teflon o-ring [6]. Install all parts the
order they were removed. Install flated portion of
shafts [4] toward gears (see Figure 3). Push the
two (2) covers together, aligning the pins and
holes by hand.

OPERA

OPERA

OPERA

OPERA

OPERATION

TION

TION

TION

TION

>

>>

>

> Do not pry the halves of the flow meter
body apart using screwdrivers or other pry
tools. (This could damage the flow meter
shaft and bushings, destoying the flow meter.)
If the body does not separate easily, replace
two (2) of the bolts near the sensor holes and
only screw them in two or three threads in the
bottom half of the body. Then, hold the top
half of the body in your hand and tap on the
bolt heads using a soft headed hammer to jar
the body halves apart.

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N

!

ARCHIVE