RF 1 Fiber Optic - Installation

>

>>

>

>

Flow rates lower than approxi-

mately 10cc/min. will not be detect-
ed in either forward or reverse di-
rection.

N O T E

N O T E

N O T E

N O T E

N O T E

V

V

V

V

Verifying a New Installation

erifying a New Installation

erifying a New Installation

erifying a New Installation

erifying a New Installation

The fiber optic transmitter / receiver system
contains two (2) diagnostic LEDs that are located
in the receiver. These indicators make it easy to
verify proper operation.

To verify proper operation perform the following
steps:

1. Cause fluid to flow in the meter in the forward
direction at a flow rate greater than 10cc/min.

2. Observe the diagnostic LEDs located on the
receiver PCB. The green “forward” LED should be
flashing. One flash is generated each time a gear
tooth passes the pickup tip.

Figure 16: Receiver Output Circuit Diagram

Figure 16: Receiver Output Circuit Diagram

Figure 16: Receiver Output Circuit Diagram

Figure 16: Receiver Output Circuit Diagram

Figure 16: Receiver Output Circuit Diagram

3. The flashing green led verifies the transmitter,
fiber cabling, and about 75% of the receiver
circuitry.

4. The system should be functioning normally
at this point. If it is, replace the cover on the re-
ceiver. If not, proceed to the following trouble-
shooting section.