Archive, System verifica – Ransburg RF1 FiberOptic Meter 77786-XX, A11516-XX User Manual
Page 21
FM-00-02.5
1 7
1 7
1 7
1 7
1 7
RF 1 Fiber Optic - Installation
>
>>
>
>
Flow rates lower than approxi-
mately 10cc/min. will not be detect-
ed in either forward or reverse di-
rection.
N O T E
N O T E
N O T E
N O T E
N O T E
V
V
V
V
Verifying a New Installation
erifying a New Installation
erifying a New Installation
erifying a New Installation
erifying a New Installation
The fiber optic transmitter / receiver system
contains two (2) diagnostic LEDs that are located
in the receiver. These indicators make it easy to
verify proper operation.
To verify proper operation perform the following
steps:
1. Cause fluid to flow in the meter in the forward
direction at a flow rate greater than 10cc/min.
2. Observe the diagnostic LEDs located on the
receiver PCB. The green “forward” LED should be
flashing. One flash is generated each time a gear
tooth passes the pickup tip.
Figure 16: Receiver Output Circuit Diagram
Figure 16: Receiver Output Circuit Diagram
Figure 16: Receiver Output Circuit Diagram
Figure 16: Receiver Output Circuit Diagram
Figure 16: Receiver Output Circuit Diagram
3. The flashing green led verifies the transmitter,
fiber cabling, and about 75% of the receiver
circuitry.
4. The system should be functioning normally
at this point. If it is, replace the cover on the re-
ceiver. If not, proceed to the following trouble-
shooting section.