TROUBLESHOOTING GUIDE

Fluid

Air (to CCV)

Air

Fluid

Air

Fluid

1. No main supply air

2.

No paint connected to CCV

3. Paint not pressurized

1. No main supply air

2. Loose connection

1. Hole in tubing

2. Loose connections

1. Loose connection

2. Worn fluid tubing

1. Insufficient supply air

1. Low supply pressure

2. Clogged or obstructed fluid lines

3. Clogged or obstructed CCV stack

1. Turn supply air on.

2. Reconnect paint.

3. Check users supply.

1. Turn supply air On.

2. Tighten connections.

1. Replace worn tubing.

2. Tighten connections.

1. Tighten connections.

2. Replace worn fluid tubing.

1. Check air regulator.

1. Increase supply pressure.

2. Clean or replace.

3. Clean as required.

General Problem

Possible Cause

Solution

DELIVERY

LEAKAGE

DEFICIENT DELIVERY

14

Color Valve Stack - Maintenance

LN-9113-06.3