beautypg.com

Installation, Ransburg, Color valve stack - installation – Ransburg Color Valve Stack CCV-5100 User Manual

Page 12

background image

INSTALLATION

Figure 1: Typical Color Change Stack

* Included in KK-4901 Manifold Assembly Kit.

LSFI0033 Adapter

9

Color Valve Stack - Installation

LN-9113-06.3

Ransburg

The CCV-403-SS valve mounted at this position is used

for solvent flushing of the manifold assembly. Connect the

solvent feed line to this valve. (Check valve is always used

on input port of CCV).

Check valves are always used on input ports of Air Push and

Solvent CCV’s They are optional for Color CCV’s.

GA-338 Gauge

HAR-503-1 Air Regulator

23165-430* O-Ring (not shown)

The CCV-403-SS valve

mounted at this position is

used for air push of the man-

ifold assembly. Connect the

main air line to the regulator.

(Check valve is always used

on input port of CCV.)

CCV-16-SS Manifold Block

SSF-6504* Threaded rod - 4 required.

Cut to proper length at assembly.

SS-655-ZN* Nut - 4

required. (tighten to

110-130 in lbs)

CCV-37 Manifold

Mounting Bracket - 2

required

CCV-18-SS

Open Manifold End Cap

Fluid Inlets -

Fittings must

be specified on Standard

Stacks. Tee fittings (SSP-

6810, 3/8” Male Branch Tee)

or 3/8” Elbows (SSP-6435)

may be used. Plug opposite

port with SSP-1421 Pipe

Plug if necessary.

Use nylon tubing for all fluid

lines, 1/4” O.D. or larger.

Do not use polyethylene

for fluid.

SS-10022* Cap Screw (4) required

CCV-17-SS End Valve Manifold Block

NOTE: