Mounting The Color Changer

There are three mounting configurations as fol-

lows (reference Figure 3):

• 5/16” clearance holes for flush mounting to

the booth wall

• 1/4” x 20 threaded holes in the end blocks

• 1/4” x 20 threaded holes in the back of the

end blocks

Figure 4: Grounding the Color Changer

Grounding of the Color Changer

For safety, the color changer MUST be grounded.

Using a 12-gauge wire, ground the output plate of

the color changer to a true earth ground. Using

an ohm meter, check for ground, testing the earth

ground to the purge assembly top plate. The

resistance should be 10 ohms or less.

Figure 3: Mounting Configurations Footprint

> The color changer MUST be properly

grounded. Proper grounding (as described

below) will prevent static charge buildup and

possible discharge from the color changer.

W A R N I N G

!

1/4-20 UNC - 2B

1/4-20 UNC - 2B

78074-00

OUTLET

ASS'Y.

78070-00

PUREGE ASS'Y.

EARTH GROUND

(TRUE)

OHMS

0

10

PURGE ASS'Y.

TOP PLATE

MCV Color Changer - Installation

CS-01-01.8

11

Ransburg