beautypg.com

Ransburg – Ransburg HV Controller A12311 User Manual

Page 15

background image

Mode Menu

Figure 11: Voltage Mode Screen

This menu displays the current mode (Voltage or

Current) and the high and low limits allowed for

the Dependent Value in that mode. All of these

values are changeable values.

Sensitivity Menu

Figure 12: Sensitivity Menu Screen

This menu displays the current di/dt or dv/dt

limit value and the enable status for di/dt or dv/dt

depending on the mode. These are changeable

values. If the current/voltage changes greater

than this value within approximately 100ms, a

fault signal is issued.

Fault Menu

Figure 13: Fault Menu Screen

This menu displays the latest fault and is displayed

automatically upon the fault detection.

Display Contrast Menu

below the password digit being changed instead of

beside them. When the new password is entered,

it will now be used for all values being changed.

Figure 14: Display Contrast Menu Screen

High Voltage Controller - Operation

13

Ransburg

LN-9623-00.1