beautypg.com

Ransburg, Buttons – Ransburg HV Controller A12311 User Manual

Page 11

background image

NOTES

Fault LED

The red Fault LED is lit when the system detects

a fault condition (see "Figure 3 - Power Switch" in

this section). When operating in "Local Mode", it

is cleared by flipping the HV On/Off switch to the

Off (Reset) position. If the system is still in a fault

condition, it will immediately be lit as the system

detects the fault.

High Voltage LED

The green High Voltage LED displays the current

state of the High Voltage Output. This LED is illu-

minated whenever High Voltage is being supplied.

BUTTONS

The six buttons used to control the viewing and

entry of information on the 4 X 20 character dis-

play are:

Screen Button

The Screen Button (at the top) is used to change

(toggle) to the next Menu screen. The menu

screens wrap around so that after the last screen

it will return to the first screen.

Up and Down Buttons

The buttons above and below the Set Button in

the middle (the Up and Down Buttons) are used to

change which value on the screen is to be changed.

Set Button

This labeled button (in the middle) is used to select

the value to change and to enter the change after

it has been made.

Increase and Decrease Buttons

The buttons to the right and left of the Set Button

are the Increase and Decrease Buttons. They

are used to change the value selected by the

Set Button.

High Voltage Controller - Introduction

9

Ransburg

LN-9623-00.1