Trinity 6 DMX Specifications

Input

Output

System Protection

Safety and EMI/EMC

Environmental

Control Interface

Rated Input Voltage

115 to 277 Vac hard wired

Rated Input Frequency

50 - 60 Hz

Power Factor EN61000-3-2

@ 115 or 277 Vac, 100% load, 0.97 W/VA min

Input Current Total Harmonic Distortion @ 115 or 277 Vac, 100% load, 13% max

Rated Output Power

@ 40°C / 104°F ambient, 243 W max

Output Voltage

6 to 27 Vdc

Efficiency

87% with 100% load @ 277 Vac input

System Power Cycle Delay

2 second typical time required for stabilization of all outputs

Output Current Tolerance

+/-5 % of nominal

Output

Over voltage, over current, short circuit protection

Over Temperature

Power supply will shut down when external ambient temperature
exceeds 43°C/ 109.4°F or case temperature reaches 85°C/ 185°F
nominal.

Output Interconnection

Hiccup mode with automatic recovery upon removal of short.

Agency Approvals

UL 60950-1, IEC60950-1, SELV, Class 2 outputs, LPS standard UL8750

Conducted and Radiated Emissions

EN55022; ICES-003; FCC Title 47, Part 15, Class A (for commercial use
only); EN55015 Conducted (external filter required)

EMC

EN61547- general lighting

Location Rating

Dry

Operating Ambient Temperature

-20°C to 40°C / -4°F to 104°F

Cold Start Temperature

-20°C / -4°F

Storage Ambient Temperature

-40°C to 80°C / -40°F to 176°F

Relative Humidity

5% to 95% noncondensing

Mean Time Between Failure
(MIL HDBK-217F); (12 channel)

>60,000 hours @ 40°C / 104°F; >97,000 hours @ 25°C / 77°F

Control Method

DMX512-A

DMX Receiver Isolation

Isolated from earth ground

Start Codes

Will only respond to NULL START code

Loss of DMX Input Signal

Outputs will go to 100% light intensity in less than 1 second.