beautypg.com

Alliance Laundry Systems F232157R7 User Manual

Page 32

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming

F232157

30

Table 4

(*) For certain 125 models, the RPM may display.

NOTE: ON appears ONLY where motor control

outputs are on (otherwise they are off). Outputs

referenced are on control unit fuse board. Outputs

are as labeled on the fuse board.

Table 5

NOTE: For variable-speed machines smaller than

C80, SPn1 and SPn2 are not the same speed.

Table 4 (Continued)

Pause 5 seconds, then
Reverse wash speed –
2 minutes, then pause
several seconds before
entering drain (next step)

Display shows “rEv”

Outputs: Motor operates wash speed reverse; drain closed

Drain (cannot advance to
spin here)

For 2 speed models: Display flashes “drAI”/ “For” (keypad RINSE LED on)
For variable-speed models: Display flashes “drAI”/ “For” while operating in low speed
forward; then flashes “drAI”/ “dISt” while operating at distribution speed.
If balance fails, repeats the “drAI”/ “For” then “drAI”/ “dISt” sequence above and balance
indicator is on during “drAI”/ “For” message (rebalance attempt). Tries up to 10 times in
TEST cycle then aborts test cycle.

Outputs: Drain closed for first part of step (less than 20 seconds), then drain off.
2 speed models: Wash speed forward
Variable-speed: Forward during “drAI”/ “For”; distribution during “drAI”/ “dISt”.

Spin – 3 minutes

For 2 speed models: display shows “SPn” (keypad SPIN LED on)
For variable-speed models: display shows “SPn1” (keypad SPIN LED on)
Outputs: Spin (low spin for variable speed-see motor chart below)(*)

Highest Spin speed
(variable-speed models
ONLY) – 3 minutes

For 2 speed models: this step is skipped (goes to coast, the next step)
For variable-speed models: display shows “SPn2” (keypad SPIN LED on)

Outputs: Highest spin speed selected (see motor chart below)(*)

Coast

Displays “SdLY” (spin delay coast)

Outputs: all off

Stop routine.

Display shows “01” (1 minute remaining). Agitates briefly then unlocks the door, shows
“dOnE” while sounding the buzzer 10 seconds; “dOnE” shows for 20 more seconds.
(DOOR LED on while showing “dOnE”, meaning “door ready to open”).

Motor Speed Chart

Variable-speed motor control outputs –

applies only for variable-speed models 2 speed motor outputs

STF

STR

RH

RM

RL

Fwd

Rev

Spin

Motor off (no rotation)

Wash speed forward

ON

ON

ON

Wash speed reverse

ON

ON

ON

Distribution (variable-speed ONLY)

ON

ON

NA

NA

NA

Spin (low spin speed “SPn1” for variable-
speed)

ON

ON

ON

ON

Highest spin (“SPn2” – variable-speed ONLY)

ON

ON

ON

NA

NA

NA

NA – Not Applicable