Programming

15

F232157

Programming Vend Price
(For Earlier Models)

Setup Mode

NOTE: In SETUP Mode, certain machine

functions can be configured. The settings in this

mode are related to how the machine is equipped

from the factory. Usually, these would not be

changed in the field.

NOTE: Enter SETUP Mode through the

PROGRAM Mode. Refer to Entering Program

Mode.

1. Press (*) keypad. Display shows machine model

size (capacity). Displayed capacity must match

machine size.

2. Press (

∧) keypad to change the capacity. (This

should already be set correctly from the factory,

and normally should never need to be changed).

3. Press START (Enter) keypad.
4. Display shows “FAr” or “CEL”.

NOTE: This option selects whether temperatures

display in degrees Fahrenheit (F) or Celsius (C), if

control is equipped with a temperature sensor.

Press the (

∧) or (∨) keypad to change degrees

“FAr” or “CEL”.

5. Press START (Enter) keypad.
6. If model displays “HEAt” or “noHt”, change the

selection by pressing the (

∧) or (∨) keypad.

7. If model displays “CArd” or “COIn”, skip to

step #10.

8. Press START (Enter) keypad to continue to the

next step.

9. “EFIL” or “nEFL” will display in certain models.

“EFIL” means the capability to control an extra

fill valve with programmable water level (same

as regular fills) is enabled. Machine MUST be

equipped with the extra valve for this to work

properly. “nEFL” means the extra fill valve

option is disabled or not installed on machine.

NOTE: If neither message displays, the extra fill

capability is not present. If either message displays,

changing the selection is an option by pressing the

(

∧) or (∨) keypad. Press START (Enter) keypad

to continue to the next option.

10. If model displays the message “CArd” or

“COIn”, change the selection by pressing the (

∧)

or (

∨) keypad.

11. When correct, press START (Enter) keypad to

continue to the next selection.

NOTE: Select “COIn” for regular coin drop meter

or if coin inputs are used by accessory pay system.

Contact the manufacturer of the accessory pay

system if not working properly.

12. “bEEP” or “nobP” will display in certain models.

If “bEEP” is set, control will beep during Add

Bleach (Supply 2) and at end of cycle after

several seconds while displaying “dOnE”. If

“nobP” displays, control will NOT beep during

Add Bleach (Supply 2) or at end of cycle. This

does not affect the short beep when a keypad is

pressed or a coin is inserted and it does not affect

the beep during an alarm.

13. Press the (

∧) or (∨) keypad to change “bEEP”/

“nobP” selection.

14. Press START (Enter) keypad to continue to next

step.