beautypg.com

To edit an entire wash cycle formula, Wash 1 – wash 4, Table 3 for op – Alliance Laundry Systems F232157R7 User Manual

Page 26: Warning

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming

F232157

24

To Edit an Entire Wash Cycle
Formula

1. Enter PROGRAM Mode. Refer to Entering

Program Mode.

2. Press the (

∧) keypad until display shows

“CY01”.

3. Press the (

∧) or (∨) keypad until cycle to be

edited is displayed.

4. Press START (Enter) keypad to select the cycle

desired. Refer to Figure 3, showing which cycle

number corresponds to each keypad when in

RUN Mode.

Agitation for the cycle

5. With display showing “CY_x” (x = cycle

number), press the START (Enter) keypad.

6. Display shows either “nor

n

” (for normal

agitation), or “GEnt” (for gentle agitation). Refer

to Table 3.

7. Press the (

∧) or (∨) keypad to alter the selection,

or the START (Enter) keypad to continue.

Wash 1 – Wash 4

NOTE: Programming a time other than “00” for

Wash 1 will make the WASH indicator LED light

while this step is running, but NOT in PROGRAM

Mode.

8. The main display shows “USH1” indicating you

are in the Wash segment (number will reflect

selected Wash cycle 1-4).

9. Press START (Enter) keypad. Display shows

agitation time during the step: “00” (skips

segment) or 2-30 minutes. Wash 2 agitation’s

time can be 2-20 minutes, 2-15 minutes for Wash

3 and Wash 4 or “00” to skip Wash 2, Wash 3 or

Wash 4. This is the time after the fill and before

the drain and does not include spin time or time

to first reach a programmed temperature (if

machine is configured for heat).

10. Press the (

∧) or (∨) keypad to alter the selection,

or the START (Enter) keypad to continue.

11. Display shows “CFIL”, “HFIL”, “bFIL” or

“EFIL” for Cold, Hot, Both (warm) or Extra fill,

respectively.

12. Press the (

∧) or (∨) keypad to alter the selection,

or the START (Enter) keypad to continue.

NOTE: Extra fill (“EFIL”) is possible only if

configured for “EFIL” in SETUP Mode. If model is

not configured for the extra fill valve, “nEFL” will

display. If configured, a third valve can be

controlled.

13. Display shows “LO”, “

n

Ed”, or “HI” for Low,

Medium, or High water level, respectively.

14. Press the (

∧) or (∨) keypad to alter the

selection, or the START (Enter) keypad to

continue.

15. Display shows “SUP0”, “SUP1”, “SUP2”,

“SUP3”, or “SUP6” (or “S 12” depending on

version of control). Refer to Table 2 for operation

of each supply selection.

16. Press the (

∧) or (∨) keypad to alter the selection,

or the START (Enter) keypad to continue.

NOTE: If programmed for “SUP2”, the ADD

BLEACH indicator LED light turns on and is set

up for “bEEP” the buzzer sounds for the first eight

seconds Supply 2 is on.

Heated Models Only

17. Display shows temperature in degrees F or C.

Display will show degrees F if configured for

“FAr” in SETUP Mode, or degrees C if

configured for “CEL” in SETUP Mode. Range is

80°F to 205°F, or 00F (no heat for segment), or

27°C to 95°C, or 00C (no heat for segment).

18. Press the (

∧) keypad to increase, or (∨) keypad

to decrease temperature in one-degree

increments.

The control will energize heat and pause cycle timing

for up to 40 minutes until the programmed

temperature is first reached.

Display

Meaning

nor

n

12 seconds forward, 3 seconds pause,
12 seconds reverse, 3 seconds pause, and
repeat for programmed time.

GEnt

3 seconds forward, 12 seconds pause,
3 seconds reverse, 12 seconds pause and
repeat for programmed time

Table 3

To prevent personal injury, avoid contact

with inlet water temperatures higher than

125° Fahrenheit (51° Celsius) and hot

surfaces.

W748

WARNING