beautypg.com

Cuhl”), Temperature probe malfunction, How to rapid advance (during first fill step) – Alliance Laundry Systems F232157R7 User Manual

Page 29

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming

27

F232157

Drain Error (For Models With Firmware ID
Code “C2dS” and “CvdS”)

If machine has not drained within 4 minutes 15

seconds, display flashes “Erdn”, time remaining, and

buzzer beeps. The buzzer stops beeping after 30

seconds while display flashes “Erdn” until machine

empties. If machine empties, ending Drain Error

condition, display stops flashing, buzzer turns off, and

remaining cycle time displays as the cycle resumes.
If machine does not empty, display continues flashing

“Erdn”. The drain error counter increases by one.

Refer to Cycle and Error Count section.

Clogged Filter (All C80 and C60 X Voltage
ONLY Models)

A clogged filter can cause the inverter drive to run at

an elevated temperature. If the control senses an

elevated inverter drive temperature, the bottom

indicator LED on front panel decal lights. Check and

clean the drive compartment filter if necessary. The

light turns off AFTER one cycle runs at normal

temperature.

Door Will Not Unlock

If the door solenoid cannot retract (unlocking the door)

at the end of the stop routine, the display will show

“----” for ten seconds. In all models except an early

version of the 125, control attempts to unlock the door

again by pulsing the door solenoid every ten seconds

for a total of five times. An early version of the 125

model has a door unlock button.
The display then flashes “CAnt”/“OPEn”, indicating it

cannot unlock the door. This indicates a problem, and

a qualified service technician should be consulted.
At the end of a cycle or at power up, before the control

will allow the door to unlock, control checks for low,

medium or high water level. Control allows the door to

unlock only when machine is empty. If any water level

is indicated, display shows “FULL” while keeping all

outputs off. This condition could indicate a slow drain

system or a mechanical blockage of the drain. Contact

an authorized service person, mentioning display on

control.

On Board Battery Problem

If certain functions require the on board battery

(dependent on specific machines) and if battery charge

is low, or battery is removed, the control will display

“bAtt”. This is displayed several seconds after power

is applied to the control. Contact an authorized service

person if condition continues.

Temperature Probe Malfunction

If display shows “+SFL”, “-19C”, or “00F”, the

temperature probe may need to be replaced. If problem

persists after changing probe, contact an authorized

service person.

Rapid Advance (For Models With
Firmware ID Code “C2dS” and
“CvdS”)

Enabling Rapid Advance

NOTE: Rapid Advance can only be used during a

cycle operation.

To enable Rapid Advance while a cycle is in progress,

machine must be in PROGRAM Mode. Refer to

Entering Program Mode.

How to Rapid Advance During All Steps
(Except First Fill Step)

1. Make sure Rapid Advance is enabled.
2. Enter PROGRAM Mode. Refer to Entering

Program Mode.

3. Press the Advance (

∧) keypad to advance to

desired step.

4. Display will show recalculated time remaining.

How to Rapid Advance (During First Fill
Step)

1. Make sure Rapid Advance is enabled.
2. While machine is filling with water, enter

PROGRAM Mode. Refer to Entering Program

Mode.

3. To advance to the next step, press START

(Enter) keypad to turn off the ability to change

cycles.

4. Press the Advance (

∧) keypad to advance to

desired step.

5. Display will show recalculated time remaining.

NOTE: If control is set up for ‘Eti

n

’, the remaining

cycle time after using Rapid Advance step is

calculated as if control was configured for ‘Pti

n

’.

This is because any time estimations following

advance would be inaccurate. After the cycle ends,

and the ADVANCE Mode is disabled, the next cycle

display remaining cycle time based on the ‘Eti

n

configuration.