Chapter 36: Line Commands
You can access the onboard configuration program by attaching a VT100
compatible device to the server’s serial port. These commands are used to set
communication parameters for the serial port or Telnet (i.e., a virtual terminal).
line
This command identifies a specific line for configuration, and to process subsequent
line configuration commands.
Syntax
line {console | vty}
• console - Console terminal line.
• vty - Virtual terminal for remote console access (i.e., Telnet).
Default Setting
There is no default line.
Table 36-1 Line Commands
Command
Function
Mode
Page
line
Identifies a specific line for configuration and starts the line
configuration mode
GC
login
Enables password checking at login
LC
password
Specifies a password on a line
LC
timeout login
response
Sets the interval that the system waits for a login attempt
LC
exec-timeout
Sets the interval that the command interpreter waits until user
input is detected
LC
password-thresh
Sets the password intrusion threshold, which limits the number of
failed logon attempts
LC
silent-time
*
* These commands only apply to the serial port.
Sets the amount of time the management console is inaccessible
after the number of unsuccessful logon attempts exceeds the
threshold set by the password-thresh command
LC
databits
*
Sets the number of data bits per character that are interpreted and
generated by hardware
LC
parity
*
Defines the generation of a parity bit
LC
speed
*
Sets the terminal baud rate
LC
stopbits
*
Sets the number of the stop bits transmitted per byte
LC
disconnect
Terminates a line connection
PE
show line
Displays a terminal line's parameters
NE, PE