VLAN Configuration

23-18

23

Figure 23-1 Tunnel Port Configuration

CLI – This example sets port 1 to tunnel access mode, indicates that the TPID used
for 802.1Q tagged frames is 9100 hexadecimal, and sets port 2 to tunnel uplink
mode.

Console(config)#interface ethernet 1/1

45-1

Console(config-if)#switchport dot1q-tunnel mode access

52-14

Console(config-if)#switchport dot1q-tunnel tpid 9100

52-15

Console(config-if)#interface ethernet 1/2

Console(config-if)#switchport dot1q-tunnel mode uplink

52-14

Console(config-if)#end

Console#show dot1q-tunnel

52-16

Current double-tagged status of the system is Enabled

The dot1q-tunnel mode of the set interface 1/1 is Access mode, TPID is 0x9100.
The dot1q-tunnel mode of the set interface 1/2 is Uplink mode, TPID is 0x8100.
The dot1q-tunnel mode of the set interface 1/3 is Normal mode, TPID is 0x8100.
The dot1q-tunnel mode of the set interface 1/4 is Normal mode, TPID is 0x8100.
The dot1q-tunnel mode of the set interface 1/5 is Normal mode, TPID is 0x8100.
The dot1q-tunnel mode of the set interface 1/6 is Normal mode, TPID is 0x8100.
The dot1q-tunnel mode of the set interface 1/7 is Normal mode, TPID is 0x8100.
.
.
.
.
The dot1q-tunnel mode of the set interface 1/24 is Normal mode, TPID is 0x8100.
Console#