Kasco Marine J Series User Manual

Page 3

background image

Single Phase

208-240 Volt

8400JF

3.1JF

5.1JF

Control box

connection

C-85

Hardwire at

shore

C-85

Hardwire at

shore

C-95

Hardwire at

shore

Aerator

connection

plug or

hardwire

into C-85

plug or

hardwire

into C-85

hardwire

into C-95

3 phase 208-

230 Volt

2.3JF

3.3JF

5.3JF

7.3JF

Voltage

208

208

208

208

Amps @208V

7.5

10.3

16.0

20.0

Lock rotor

amps

40

70

100

100

3 phase 460

Volt

2.3HJF 3.3HJF 5.3HJF 7.3HJF

Voltage

460

460

460

460

Amps

3.6

5.1

7.8

10.0

Lock rotor

amps

24

40

49

50

Parts Included

8400JF, 3.1JF, or 5.1JF Aerator

2.3JF, 3.3JF, or 5.3JF Aerator

(Unit with cord or unit with Disconnect) (1)

A1. Cord in separate box (1) (depending on size of cord)

B. Float in separate box (1) (Diagram)

1. 3 Float Sections (1)

2. Top Float Bracket (3)

3. Bottom Float Bracket w/ 50’ rope (3)

4. 9” x 3/8” Black Coated Bolt (6)

5. 3/8” Lock Nut (6)

6. Bottom Screen (1)

7. Top Screen (1)

8. Top Screen Clip (3)

9. 1/4-20 x 3/4” Brass Screw (3)

10. 1/4” Lock Washer (3)

11. 1/4 nut (3)

12. Bottom Screen Clip (3)

13. 3/8-16 x 1” Bolt (3)

14. 3/8 lock washer (3)

15. Mesh screen (1)

16. Cable ties (10)

the other for balance. Note: It is extremely important

to test the GFCI in the control panel upon each instal-

lation/reinstallation of the unit to ensure proper func-

tioning.

USE AND OPERATION

Kasco Aerators are designed and engineered for

continuous duty, such as on fish farms or other aqua-

culture applications, or on-demand use, as needed in a

recreational water feature.

During flotation operation, the water is pulled from
360

O

around the unit and from below the unit. The

water is pulled upward and thrust through the flotation

collar into the air.

Your Kasco Marine aerator is ready for immediate use

(after installation). Make sure to keep the motor hous-

ing clean from hard water deposits and/or algae. (See

Maintenance Recommendations)

It is extremely important that proper and sufficient

voltage is supplied to the aerator motor. Unit should

be protected by a GFCI. Control panels must be

installed by a qualified electrician. (See Installation

instructions).

Kasco aerators are lightweight, energy efficient, and

easy to install and operate. We strive to produce prod-

ucts that exceed customer expectations. We hope you

enjoy your Kasco aerator.

UNIT STORAGE

When storing units during the offseason, it is impor-

tant to store them upside down if they are going to be

sitting for long periods of time. Units that sit upright

on a shelf for many months, or even years have a

greater likelihood of seals drying out. Storing upside

down will ensure oil is lubricating the seals and pre-

vent drying.

Unit Specs

Single Phase

208-240 Volt

8400JF

3.1JF

5.1JF

Voltage

208-240

208-240

208-240

Amps

10.5

13.4

20

Lock rotor

amps

40

61

97