Kasco Marine 4400HJF User Manual

Page 12

background image

12

L1 __________

L2 __________

Date installed _____/_____/_____

Any unauthorized modifications to this control panel

will void the UL listing and the Kasco warranty.

C-25 Timer Control Instructions

Portable Timer with Ground Fault Interrupter

(Unit: 9.8 FLA, 58.8 LRA 120 VAC

Light: 300 W, 120 VAC)

IMPORTANT

This portable timer is designed for CONTROLLING the

connected equipment only. Unplug timer before servic-

ing the unit or the equipment it controls. THE MANUAL

OVERRIDE KNOB IS NOT TO BE USED AS A POWER

DISCONNECT! For maximum protection against electri-

cal shock hazard, perform test procedure on G.F.C.I. at least

once a month. Mount at least 5 ft. from open water.

G.F.C.I. TEST PROCEDURE

The G.F.C.I. should be checked every month to make sure

that it is operating properly. Just follow the simple instruc-

tions below. It is recommended to maintain a maintenance

diary of your monthly safety check.

1. Push TEST button, RESET button should pop out from

inner surface. This should result in power being OFF at

the outlet protected by the G.F.C.I. Verify by plugging a

test lamp into the outlet. Be sure the timer is in the ON

position.

2. If the G.F.C.I. tests okay, restore power by pushing the

RESET button back in. THE RESET BUTTON MUST BE

PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT

LOCKS AND RE-MAINS DEPRESSED AFTER PRES-

SURE HAS BEEN REMOVED.

DANGER: IF RESET BUTTON DOES NOT POP OUT,

IF TEST LAMP REMAINS LIT WHEN RESET BUTTON

DOES POP OUT, OR IF THE G.F.C.I. FAILS TO RE-

SET PROPERLY, DO NOT USE TIMER! CONTACT A

QUALIFIED SERVICE TECHNICIAN!

Failure to use the C-25 with Kasco Fountains will void the

warranty and cause the Fountain to not be listed to UL and

CSA standards via ETL.

UNDER NO CIRCUMSTANCES SHOULD ANYONE

should be stripped back at least 3inches. Follow the

connection diagram for terminating these three wires

to the terminal blocks in the control panel.

Black connects to Terminal #4

White connects to Terminal #5

Green connects to Terminal G

Light Kit connection:

If you purchased a Kasco light kit(s) for your aerator,

follow the light kit installation instructions for

mounting the light kit(s) to the aerator float.

This control panel requires a hardwire connection for

the light kit(s). To connect the light kit(s) you will

need to cut off the power cord plug that is molded to

the light kit power cord. Strip back the black outer

jacket of the light kit power cord at least 3inches

to reveal the three internal wires of the power cord.

(black, white, and green conductors). These three

wires will need to be stripped back 1/2”. Follow the

connection diagram for terminating these three wires

to the terminal blocks in the control panel.

Light kit connections:

Black connects to Terminal #6

White connects to Terminal #7

Green connects to Terminal G

STEP FOUR:

Test the GFCB with the test button now and every

30 days.

If lights are installed, they can now be installed per

Instructions included with the lights.

Once completed, power can be restored to the panel.

Record the following data while the Aerator is

operating in the water under load:

Voltage:

L1-L2 ________

L1-N _________

L2-N _________

Amperage:

This manual is related to the following products: