background image

GENERAL PUMP

A member of the Interpump Group

SM SERIES

Page 10

Slowly screw in the 3 M8 screws (1, fig. 24) to prevent the box from tilting too far and getting locked in the

housing. Remove the box while supporting the crankshaft to prevent damage (1, fig. 25).

Unscrew the bearing cover fixing screws from the opposite side (1, fig. 27).

Position the 3 grub screws or M8 threaded screws (1, fig. 23) with the function of extractors in the holes and

two sufficiently long M10 screws with the function of supporting the reduction gear box (2, fig. 23).

Ref 300894 Rev.A

06-12