beautypg.com

Electric motor horsepower required to drive a pump, Spray tip selection chart – General Pump Pump Installation and Service Manual User Manual

Page 4

background image

4

ELECTRIC MOTOR HORSEPOWER REQUIRED TO DRIVE A PUMP

GPM

100 PSI

200 PSI

250 PSI

300 PSI

400 PSI

500 PSI

700 PSI 1000 PSI 1250 PSI 1500 PSI 2000 PSI 2500 PSI 3000 PSI 4000 PSI

.5

.04

.07

.09

.11

.14

.18

.26

.35

.44

.53

.70

.88

1.10

1.40

1.0

.07

.14

.18

.21

.28

.35

.52

.70

.88

1.05

1.40

1.76

1.92

2.80

1.5

.10

.21

.26

.31

.41

.52

.77

1.03

1.29

1.55

2.06

2.58

3.09

4.12

2.0

.14

.28

.35

.42

.56

.70

1.04

1.40

1.76

2.10

2.80

3.53

4.20

5.60

2.5

.17

.34

.43

.51

.69

.86

1.29

1.72

2.15

2.58

3.44

4.30

5.14

6.88

3.0

.21

.42

.53

.63

.84

1.05

1.56

2.10

2.64

3.15

4.20

5.28

6.30

8.40

3.5

.24

.48

.60

.72

.96

1.20

1.80

2.40

3.00

3.60

4.80

6.00

7.20

9.60

4.0

.28

.56

.70

.84

1.12

1.40

2.08

2.80

3.52

4.20

5.60

7.04

8.40

11.20

5.0

.35

.70

.88

1.05

1.40

1.75

2.60

3.50

4.40

5.25

7.00

8.80

10.50

14.00

6.0

.42

.84

1.05

1.26

1.68

2.10

3.12

4.20

5.28

6.30

8.40

10.56

12.60

16.50

7.0

.49

.98

1.23

1.47

1.96

2.45

3.64

4.90

6.16

7.35

9.80

12.32

14.70

19.60

8.0

.56

1.12

1.40

1.68

2.24

2.80

4.16

5.60

7.04

8.40

11.20

14.08

16.80

22.40

9.0

.62

1.24

1.55

1.86

2.48

3.10

4.65

6.18

7.73

9.28

12.40

15.56

18.58

24.80

10.0

.70

1.40

1.75

2.10

2.80

3.50

5.20

7.00

8.80

10.50

14.00

17.60

21.00

28.00

*Tip

Size

Orifice Dia.

(Inches)

OUTPUT VOLUME (GPM) AT VARIOUS PRESSURES (PSI)

40 PSI 100 PSI 250 PSI 500 PSI 600 PSI 700 PSI 800 PSI 1000 PSI 1200 PSI 1500 PSI 2000 PSI 2500 PSI 3000 PSI 3500 PSI 4000 PSI

2

.034

.20

.32

.50

.71

.77

.80

.89

1.0

1.1

1.2

1.4

1.6

1.7

1.9

2.0

4

.052

.40

.63

1.00

1.40

1.60

1.70

1.80

2.0

2.2

2.5

2.8

3.1

35.

3.8

4.0

4.5

.055

.45

.71

1.10

1.50

1.70

1.90

2.00

2.2

2.4

2.8

3.0

3.6

3.9

4.3

4.5

5

.057

.50

.79

1.30

1.80

1.90

2.10

2.20

2.5

2.8

3.1

3.6

4.0

4.4

4.7

5.0

5.5

.060

.55

.87

1.40

1.90

2.10

2.30

2.50

2.8

3.0

3.4

3.8

4.4

4.8

5.2

5.5

6

.062

.60

.95

1.50

2.10

2.30

2.50

2.70

3.0

3.2

3.7

4.2

4.8

5.2

5.6

6.0

6.5

.064

.65

1.00

1.70

2.30

2.50

2.70

2.90

3.3

3.6

4.0

4.6

5.2

5.7

6.0

6.5

7

.067

.70

1.10

1.80

2.50

2.70

2.90

3.10

3.5

3.8

4.3

5.0

5.6

6.1

6.6

7.0

7.5

.707

.75

1.20

1.90

2.70

2.90

3.20

3.40

3.8

4.1

4.6

5.3

6.0

6.5

7.0

7.5

8

.072

.80

1.30

2.00

2.80

3.10

3.40

3.60

4.0

4.4

5.0

5.6

6.2

7.0

7.5

8.0

8.5

.074

.85

1.30

2.20

3.00

3.30

3.60

3.80

4.3

4.6

5.3

6.0

6.7

7.4

8.0

8.5

9

.076

.90

1.40

2.30

3.20

3.50

3.80

4.00

4.5

5.0

5.5

6.4

7.1

7.8

8.5

9.0

9.5

.078

.95

1.50

2.40

3.40

3.70

4.00

4.30

4.8

5.2

5.8

6.8

7.6

8.3

9.0

9.5

10

.080

1.00

1.60

2.50

3.50

3.90

4.20

4.50

5.0

5.4

6.1

7.0

8.0

8.7

9.4

10.0

12

.087

1.20

1.90

3.00

4.20

4.60

5.00

5.40

6.0

6.4

7.3

8.4

9.5

10.4

11.2

12.0

15

.094

1.50

2.40

3.80

5.30

5.80

6.40

6.80

7.5

8.2

9.2

10.6

12.0

12.9

14.0

15.0

20

.109

2.00

3.20

5.00

7.10

7.80

8.40

9.00

10.0

10.8

12.2

14.2

16.0

17.4

18.8

20.0

30

.141

3.00

4.70

7.50

10.60

11.60

12.80

13.60

15.00

16.40

18.40

21.2

24.0

26.0

28.0

30.0

40

.156

4.00

6.30

10.00

14.20

15.60

16.80

18.00

20.00

21.60

24.40

28.4

32.0

34.8

37.6

40.0

SPRAY TIP SELECTION CHART

NOTES: 1, A gasoline engine should be sized 1.8 times the electric horsepower requirement.

2. Always select a motor/engine with a horsepower rating above the minimum requirements shown

above. Example: 5.0 GPM - 1250 PSI is 4.40 minimum electric horsepower requirement, use a

5 horsepower electric motor.

If you wish to direct drive your pump from an electric

motor, you may want to use a “C” face motor.

Check with your motor supplier for technicla

information.

* A commonly used standard for tip size is the “nozzle number” which is equivalent to the nozzle

capacity in GPM at 4000 PSI. Spray angle does not affect nozzle volume.