15. TROUBLESHOOTING

The pump does not produce any noise at

start-up:

• The pump is not primed and is running dry

• There is no water in the inlet line

• The valves are blocked

• The delivery line is closed and does not allow

the air in the pump to be discharged

The pump pulses irregularly (knocking):

• Air suction

• Insufficient feeding

• Bends, elbows, fittings along the suction line

obstruct the fluid’s passage

• The inlet filter is dirty or too small

• The booster pump, where provided, supplies

insufficient pressure or flow rate

• The pump is not primed due to insufficient

head or the delivery line is closed during

priming

• The pump is not primed due to valve seizing

• Worn valves

• Worn pressure packings

• Incorrect operation of the pressure adjust

ment valve

• Transmission problems

The pump does not deliver the rated flow / is

noisy:

• Insufficient feeding (see the causes listed

above)

• RPM are less than the rated flow

• Excessive amount of water by-passed by the

pressure adjustment valve

• Worn valves

• Leakage from the pressure packings

• Cavitation due to:

1) Wrong sizing of the suction hose/

undersized diameters

2) Insufficient flow rate

3) High water temperature

Insufficient pump pressure:

• The nozzle (or has become)too large

• Insufficient RPM

• Leakage from the pressure packings

• Incorrect operation of the pressure adjust-

ment valve

• Worn valves

Page 14

Overheated pump:

• The pump is overloaded (pressure or RPM

exceed the rated values)

• Oil level is too low, or the oil is not of a suit

able type, indicated in Chapter 7 (see para

graph 7.4)

• Incorrect alignment of the joint or pulleys

• Excessive inclination of the pump during

operation

Pump vibrations or knocking:

• Air suction

• Incorrect operation of the pressure adjust

ment valve

• Valve malfunction

• Irregular drive transmission motion