Section VII - Troubleshooting

General Notes:

Do not pump liquids containing ferrous metal fines.

If magnets decouple, stop pump immediately. Operating the

pump with the magnets decoupled will eventually weaken

the magnets.

Power monitors are required and must be used with all

ATEX certified pumps.

Do not use mismatched drive magnet assemblies (differ-

ent number of magnets on inner and outer drive magnet

assemblies).

Contact our Technical Service Department -

Phone: 1-800-888-3743

Email: [email protected]

if you have any questions regarding product operation

or repair.

Air or gas in liquid

Impeller diameter too small

System head lower than anticipated

Motors speed insufficient (too low) or motor rotation

incorrect (correct rotation when viewed from the fan end is

clockwise)

Loss of Prime

Leak in suction piping

Foot valve or suction opening not submerged enough

Foot valve too small or leaking

Air or gas in liquid

Insufficient Pressure

Foreign matter in impeller

Leaking valve. Suction lift too high or insufficient NPSHa

Excessive Power Consumption

Head lower than rating

Excessive flow

Specific gravity or viscosity too high.

Vibration/Noise

Loose magnet

Drive magnet rubbing

Pump cavitating from improper suction or feed

Motor or piping not properly secured

Foreign object in impeller

No or Insufficient Discharge

Air leaks in suction piping

Pump not primed

System head higher than anticipated

Closed valve

Viscosity or specific gravity too high

Motor too large for magnet coupling rating (magnets

uncoupled)

Suction lift too high or insufficient NPSH

Clogged suction line or impeller vanes

Motor rotation incorrect (correct rotation when viewed

from the fan end is clockwise)

Section VIII - Warranty

Finish Thompson, Inc (manufacturer) warrants this pump product

to be free of defects in materials and workmanship for a period of

five years from date of purchase by original purchaser. If a war-

ranted defect, which is determined by manufacturer’s inspection,

occurs within this period, it will be repaired or replaced at the

manufacturer’s option, provided (1) the product is submitted with

proof of purchase date and (2) transportation charges are prepaid to

the manufacturer. Liability under this warranty is expressly limited

to repairing or replacing the product or parts thereof and is in lieu

of any other warranties, either expressed or implied. This warranty

does not apply to normal wear of the product or components. This

warranty does not apply to products or parts broken due to, in whole

or in part, accident, overload, abuse, chemical attack, tampering, or

alteration. The warranty does not apply to any other equipment used

or purchased in combination with this product.

The manufacturer

accepts no responsibility for product damage or personal injuries

sustained when the product is modified in any way. If this warranty

does not apply, the purchaser shall bear all cost for labor, material

and transportation.

Manufacturer shall not be liable for incidental or consequential

damages including, but not limited to, process down time, trans-

portation costs, costs associated with replacement or substitution

products, labor costs, product installation or removal costs, or loss

of profit. In any and all events, manufacturer’s liability shall not

exceed the purchase price of the product and/or accessories.

Ordering Spare Parts

Spare parts can be ordered from your local distributor. Always refer

to the pump model to avoid error.

Part Number 107403 R12, 2/14/14
Order fax: 814-459-3460
Tech Service: 800-888-3743
Lit. ID No. FT09-1092