E.

Installation Procedure

1.

Select a location which is level and will fully support the weight of the platform plus

a full capacity load.

2.

Remove the top of the crate and all packing/banding material.

3.

Screw the two (2) eyebolts into the threaded adapters in the platform top. Use a

forklift or other lifting means along with chains, cables, or nylon straps to remove

the scale from the crate bottom.

4.

Set the scale so the interface cable exits in a direction where it can be protected.

If possible, use a cable protector to reduce trip hazards and protect the interface

cable from being damaged.

5.

Wire the scale interface cable to the proper type indicator using the following

platform wiring/ color code:

Cable Wire Color

Function

Analog Instrument

Black

(-) Excitation

(-) Excitation

Green

(+) Excitation

(+) Excitation

Yellow

Shield

Shield

White

(+) Signal

(+) Signal

Red

(-) Signal

(-) Signal

10/06

7

50783 Issue 2

~Caution~

Failure to use the proper lifting tools may result in personal injury.