D.

Bumper Guards

Bumper Guards are designed to help protect the platform from abuse resulting from ensuing

forklift traffic. The guards are slightly higher than the scale and will help deflect the forks.

1.

Place the bumper guard so it will protect the platform from nonscale traffic, but

will not touch or interfere with the platform’s movement.

2.

Drill the holes using a hammer drill. Insert anchors with the nut and washer

already ON. Tap the anchor into the hole, then tighten the nuts securely.

E.

Balance Junction Box

1.

Installation

a.

Remove the scale access cover plate.

b.

Check that all load cells have wire markers on the cable ends. If not,
identify load cells with wire markers or other means, then disconnect the
load cell wires and the main interface cable wires.

c.

Dress all wires in order to be inserted into terminal blocks.

d.

Remove balance junction box cover and loosen all gland fittings.

e.

Insert the cables into the gland fittings and connect the cables to the
appropriate terminal block. The load cell cable for load cell number one
(1) will connect to the terminal block designated one (1). This process will
continue for all four (4) load cell cables. The main interface cable will
connect to the terminal block opposite the load cell terminals.

f.

Connect the load cell cable as follows:

10/06

10

50783 Issue 2

4

4

3

3

2

2

1

1

+ SIG

- SIG

- SEN

- EXC

+ SEN

- EXC

SHLD

+E -E SH -S +S

+E -E SH -S +S +E -E SH -S +S

+E -E SH -S +S

96141