beautypg.com

Sp rea d patte rn, Using the ev-n-spred, Dual port pro adjustable shut-off system – Earthway F80 Commercial Adaptable Broadcast Spreader User Manual

Page 8

background image

Using the EV-N-SPRED

®

Dual Port PRO Adjustable

Shut-Off System

- Included with Optional F13130D Kit Tray

The EV-N-SPRED

®

Dual Port PRO Adjustable Shut-Off System is

included on all Professional models and allows the operator

to balance the spread pattern evenly across the full 180

o

spread width, regardless of the weight or size of granular

material. By closing either the right and or left side

throwing ports you can balance the spread pattern to

exacting precision without compromising spread width or

application rate.

Each EV-N-SPRED

®

Dual Port PRO Adjustable

Shut-Off System drop hole has a corresponding

1/3

rd

coverage area on the spread width of the spreader leaving a

feathered-edge for overlapping the spread path. The illustration to

the right shows each port and the corresponding

1/3

rd

coverage

area of the spread path. These ports can be adjusted to effectively

balance the spread pattern, giving equal amounts of material

across the full 180

o

spread pattern.

EV-N-SPRED

®

Dual Port PRO System Setup

Test all material prior to beginning your spreading job. You will need

a 50’ measuring tape, a small scale to weigh the material, bucket or

container to hold the material for re-weighing, chalk or a line marking

device, and (7) low baking tins. Using the EarthWay® Bag Calibrator

#77016 can greatly reduce the time needed for

determining the Setting Rates on any material but

is not mandatory to establish a setting rate.

1. Evaluate the material being spread by comparing

it to the following standard as a reference.
Large/Heavy is the size of a BB (⅛ in / 3mm), spread width is 28 - 36 feet (8.5 -

11 meters)
Medium/Mixed (½ the size of a BB), spread width is 20 - 24 feet (6.1 - 7.3 meters)
Small/Fine (the size of sand), spread width is 16 - 18 feet (4.8 - 5.5 meters)

2. Add a small amount of the material into the spreader, enough to cover

the bottom (2-3 in / 5 - 7 cm) and begin to test for spread width. Set the

stop on the gauge to #15 and push the spreader several feet /meters at

normal walking speed on a flat hard surface (where the material will be

visible), and OPEN the lever to the STOP while continuing to walk for 3-4

paces, and CLOSE the shut-off and STOP (don’t move the spreader from

that position). Measure the spread width and evaluate the spread pattern

for even distribution on either side of the spread width center line.

TIP:

Typical spread width references are listed above. The spread width that

you measure is used to calculate the actual

Setting Rate for the material.

Sp

rea

d Patte

rn

Adjustable Throwing Ports

with 8 repeatable settings

to balance the left or right

spread pattern to

the center.

Sp

rea

d Patte

rn

SPREAD WIDTH

Gauge & Lever

15

FINE

MEDIUM

LARGE

This manual is related to the following products: