beautypg.com

Earthway Spreader-Calibration User Manual

Earthway, Ev-n-spred, Sp rea d patte rn

background image

Using the EV-N-SPRED

®

Dual Port PRO Adjustable

Shut-Off System

The EV-N-SPRED® Dual Port PRO Adjustable Shut-Off System is included on all

EarthWay® professional models and allows the operator to balance the spread

pattern evenly across the full 180

o

spread width, regardless of the weight

or size of granular material. By closing either the right and or left

side throwing ports you can balance the spread pattern to exacting

precision without compromising spread width or application rate.

Each EV-N-SPRED® Dual Port PRO Adjustable Shut-Off System

drop hole has a corresponding 1/3

rd

coverage area on the spread

width of the spreader leaving a feathered-edge for overlapping the

spread path. The illustration to the right shows each port and the

corresponding 1/3

rd

coverage area of the spread path. These ports

can be adjusted to effectively balance the spread pattern, giving

equal amounts of material across the full 180

o

spread pattern.

EV-N-SPRED® Dual Port PRO System Setup

Test all material prior to beginning your spreading job. You will need a 50’

measuring tape, a small scale to weigh the material, bucket or container to hold

the material for re-weighing, chalk or a line marking device, and (7) low baking tins.

Using the EarthWay® Bag Calibrator #77016 can greatly reduce the time needed for

determining the Setting Rates on any material but is not

mandatory to establish a setting rate.

1. Evaluate the material being spread by comparing it to

the following standard as a reference.

Large/Heavy is the size of a BB (⅛ in / 3mm), spread width is 9 - 12 feet (2.8 - 3.7 meters

Medium/Mixed (½ the size of a BB), spread width is 7 - 9 feet (2.1 - 2.8 meters)

Small/Fine (the size of sand), spread width is 5 - 7 feet (1.5 - 2.1 meters)

2. Add a small amount of the material into the spreader, enough to cover the bottom

(2 - 3 in / 5 - 7 cm) and begin to test for spread width.
Set the stop on the gauge to #15 and push the spreader several feet /meters at

normal walking speed on a flat hard surface (where the material will be visible), and

OPEN the lever to the STOP while continuing to walk for 3-4 paces, and CLOSE the

shut-off and STOP (don’t move the spreader from that position). Measure the spread

width and evaluate the spread pattern for even distribution on either side of the
spread width center line.

TIP:

Typical spread width references are listed above. The

spread width that you measure is used to calculate the actual Setting Rate for the

material.

Sp

rea

d Patte

rn

Adjustable Throwing Ports

with 8 repeatable settings

to balance the left or right

spread pattern to

the center.

EV-N-SPRED

EV-N-SPRED

EarthWay

EarthWay

R

R

Sp

rea

d Patte

rn

SPREAD WIDTH

Gauge & Lever

15

FINE

MEDIUM

LARGE