CALIBRATION INSTRUCTIONS:

Loosen set-screw on Calibration

Bracket

Set adjustment dial to “0” Closed

Activate switch to extend to the

“STOP”

Slide Calibration Bracket to ensure

shut-off is closed

Calibration is now complete

To Calculate RATE SETTINGS:

Determine how much material is to

be applied per 1,000 sq./ft.

Measure off a distance of 50 feet, preferably on a paved surface such as a parking lot.

Weigh out enough of the material to be applied to fill the hopper at least half full. Record the weight for future

use.

With the unit mounted on the vehicle and the hopper at least half full of the material to be spread, position the

vehicle far enough before the beginning of the 50 foot test area so that the vehicle will achieve the desired speed

before you reach the starting line.

Select the Setting Rate position that you feel would be an appropriate setting on the ECM Module from 1 to 11.

IMPORTANT - only make Rate Adjustments with the shut-off in the CLOSED POSITION

Start the vehicle in motion and as you cross the starting line (of the 50 feet)

move the rate lever to the open position against the stop. Take care to be aware

of what is going on around you maintaining control of the vehicle.

Continue from the starting line with the unit spreading the material. As you cross

the finish line move the rate lever to the closed position.

Stop the vehicle and note the width of the spread path that was just completed.

Return to the start point and empty the remaining material from the hopper into

your weighing container and re-weigh.

OPERATING INSTRUCTIONS:

Before filling hopper, become familiar with the operation of this spreader.

(Practice the following steps)

Turn the motor switch to the “ON” POSITION, so that the impeller is turning

before going on to the next step.

While driving forward turn the ECM Control switch (wide top switch) to the “ON” POSITION, this opens the shut

off plate on the spreader.

To stop the flow of material, turn the ECM Control switch to the “OFF” POSITION, then turn the motor off when

finished.

When finished empty any remaining material from hopper.

Thoroughly wash spreader and allow to dry before storing. Lubricate all moving parts with a graphite or silicon

spray.

C L

O S

E D O P E N

Turn

ECM Rate Adjustment

1 1

1 0

9

8 7

6 5 4 3 2

1

0

Step 3

Step 4

EarthWay

®

To Calibrate loosen

set screw

slide Calibration

Bracket

Install Calibration Bracket to ECM

shaft by sliding the Calibration Bracket

on to the ECM shaft.

M80 Side

M40 Side

To install Calibration Bracket you must

determine which leg corresponds to your

spreader. Short for M40, and long

for M80

Install Control Rod on to Shut-Off from

the top down and secure with small Hair Pin

Clip. Then attach the other end of the Control

Rod to the Calibration Bracket from the

bottom up.

Tip: You may need to retract ECM to fully

closed “0” to aid in installing the Calibration

Bracket

SLID

E

Motor

Connection