Electronics International FP-5L User Manual
Page 27
Max Displayed Range (Instrument Only):
Fuel Flow:
199.9 Gals/Hr or 162.0 br Gal/Hr or 1199 Lbs/Hr or 749 Ltr/Hr.
Fuel Remaining:
999 Gals. or 811 br Gal. or 1999 Lbs. or 1999 Ltr.
Fuel Used:
999 Gals. or 811 br Gal. or 1999 Lbs. or 1999 Ltr.
Time to Empty:
19 hours 59 minutes
Aux:
+/- 1999
RS-232/422 Input Ports (FP-5L Only):
Single Line Receive Method:
RS-232C or RS-423
Dual Line Receive Method:
RS-422 or RS-485 (with 120 ohm external resistor)
Protocol:
1 Start bit, 8 Data bits, 1 Stop bit.
Baud Rate:
1200, 4800, 9600
Receive Format:
Moving Map, Northstar or NEMA.
RS-232/422 Output Port (FP-5L Only):
Transmit Method:
RS-232C Single Line.
Protocol:
1 Start bit, 8 Data bits, 1 Stop bit.
Baud Rate:
9600 (Receive Format must be set to Moving Map).
Transmit Format:
King KLN88, Garmin, or UPS.
Fuel Flow Transducer, FT-60 (Red Cube):
Range:
0.6 to 70+ GPH
Linearity:
1% over an engines normal operating range.
K Factor:
Approx. 68,000
Pressure Drop:
0.5 PSI at 28 GPH
2.0 PSI at 56 GPH
Working Press:
1000 PSI
Min. Burst Press: 4000 PSI
Temp. Range:
-65'C to 125'C
Fuel Ports:
1/4" Female NPT
Fuel Flow Transducer, FT-90 (Gold Cube):
Range:
2 to 125+ GPH
K Factor:
Approx. 33,800
Pressure Drop:
0.5 PSI at 63 GPH
2.0 PSI at 127 GPH
Working Press:
1000 PSI
Min. Burst Press: 4000 PSI
Temp. Range:
-65'C to 125'C
Fuel Ports:
1/4" Female NPT
Fuel Pressure Transducer (PT-100GA):
Range:
0 to 100 PSI
Over Press:
300 PSI without damage.
Min. Burst Press: 500 PSI
Temp. Range:
-40'C to 125'C
Material:
303 Stainless Steel
Press. Port:
1/4" Male NPT
25
Fuel Flow Transducer, FT-180 (Black Cube):
Range:
2 to 250+ GPH
K Factor:
Approx. 22,700
Pressure Drop:
0.5 PSI at 88 GPH
2.0 PSI at 176 GPH
Working Press:
1000 PSI
Min. Burst Press: 4000 PSI
Temp. Range:
-65 to 125'C
Fuel Ports:
1/4" Female NPT with #8
Female Flare Fitting