set to the highest acceptable level for the function measured. In the “AUX” Display Mode a bar in the upper
left corner of the display will be shown when the high limit has been violated. Programming this limit to “000”
disables the alarm.
Low AUX Alarm - A Low AUX Alarm may be programmed to blink the H/L AUX Warning LED when the
displayed AUX value exceeds your programmed low setpoint. Pushing any button or switch will stop the
blinking but the H/L AUX Warning LED will stay on. This limit is intended as a warning. It should be set
to the lowest acceptable level for the function measured. In the “AUX” Display Mode a bar in the lower left
corner of the display will be shown when the low limit has been violated. Programming this limit to “000”
disables the alarm.
If the "AUX" Display Mode is not going to be used, program the High and Low AUX Alarms to "000". This
will cause the display to show "OFF" when the "AUX" Display Mode is selected.
To program the High and Low AUX Alarms, perform the following steps:
A. Select the “AUX” Display Mode.
B. Momentarily push both “PRG” buttons. A bar will appear in the
upper left corner of the display and the left digit will be blinking.
You are ready to program the High AUX Alarm limit.
C. Set the High and Low Alarm limits using the following procedure:
a) Select a Digit - The Right and Left “PRG” buttons move the
blinking digit to the right or to the left.
b) Increase or Decrease a Digits Count - Moving the "STEP
Switch" to the right will increase the blinking digits count and
moving it to the left will decrease the blinking digits count.
c) Change Functions - The display will toggle between the High
and Low Alarm limits by pushing the Right "PRG" button
with the right digit blinking or by pushing the Left "PRG"
button with the left digit blinking. The High Alarm limit is
always displayed with a bar in the upper left corner of the
display and the Low Alarm limit is always displayed with a
bar in the lower left corner of the display.
d) To Exit - To exit the Pilot Programming Settings for the
"AUX" Display Mode, momentarily push both “PRG” buttons
at the same time. The programmed values will be stored in
memory and no internal batteries or external power are
required to store this information for life.
18
1580
Blinking Digits (15)
950
Blinking Digit (9)