Transport handling and storage instructions – SPP Pumps Instream User Manual
Page 4

Manual No/Rev
W23-001E / 8
Operators Instructions for
Instream Centrifugal Pumps
Our policy is one of continuous improvement and we reserve the right to alter specifications at any time
Page 4 of 16
INSLIFT1.WMF
1.7
Note any limits to the pump application 
specified in the contract documentation. 
Operation of the equipment outside these 
limits will increase the risk from hazards noted 
below and may lead to premature and 
hazardous pump failure. 
1.8
Clear and easy access to all controls, gauges 
and dials etc. MUST be maintained at all 
times. Hazardous or flammable materials 
must NOT be stored in pump rooms unless 
safe areas or racking and suitable containers 
have been provided. 
1.9
IMPROPER INSTALLATION, OPERATION 
OR MAINTENANCE OF THIS SPP PUMPS 
LTD PRODUCT COULD RESULT IN INJURY 
OR DEATH. 
1.10 Within the manual, safety instructions are
marked with safety symbols.
Hazard
This symbol refers to general 
mechanical aspects of safety. 
Hazard
This symbol refers to electrical 
safety. 
This
symbol
gives
warning of a hazard to the
pump itself, which in turn, could cause a risk 
to personal safety. 
2. Transport Handling and Storage 
Instructions 
2.1
Transport
Instream
pumps
are
despatched
fully
assembled. Pumps are protected against 
corrosion and packed for transport by normal 
road, rail and sea carriers. 
2.2
Handling
Crushing Hazard 
When lifting the pump unit, use 
lifting equipment having a safe 
working load rating suitable for the weight 
specified. Use suitable slings for lifting any 
pump not provided with lifting points. 
 
The use of suitable forklift truck and four-chain 
crane sling equipment is recommended but 
locally approved equipment of suitable rating 
maybe used. 
 
 
Pumps are usually supplied on pallets for 
handling by forklift truck, to lift from the pallet 
the pump should be slung as shown. 
Pump weight is shown on the Pump general 
arrangement drawing. 
 
2.3 
Storage
 
2.3.1 Temporary Storage for up to Six Weeks 
 
 
If the pump is not to be used immediately, it 
should be stored carefully in a horizontal 
position, in a sheltered, dry location. Additional 
rust preventative should be applied to all 
unpainted carbon steel or cast iron parts, and 
should not be removed until final installation. 
 
2.3.2 Long Term Storage 
 
Shearing Hazard 
Do NOT place fingers or hands etc. 
into the suction or discharge pipe 
outlets and do NOT touch the 
impeller, if rotated this may cause severe 
injury. To prevent ingress of any objects, 
retain the protection covers or packaging in 
place 
until
removal
is
necessary
for
installation. If the packaging or suction and 
discharge covers are removed for inspection 
purposes, replace afterwards to protect the 
pump and maintain safety. 
For special protection of electric motors, refer 
to the manufacturers' instructions. in the 
Appendix l. 
 
2.3.3 Exposed or Extreme Conditions Storage
For exposed storage or extreme variants in 
atmospheric or environmental conditions, 
please refer to SPP Pumps Ltd. for special 
storage instructions to suit the conditions 
applicable. 
ATTENTION