Transport handling and storage instructions – SPP Pumps Instream User Manual
Page 4
Manual No/Rev
W23-001E / 8
Operators Instructions for
Instream Centrifugal Pumps
Our policy is one of continuous improvement and we reserve the right to alter specifications at any time
Page 4 of 16
INSLIFT1.WMF
1.7
Note any limits to the pump application
specified in the contract documentation.
Operation of the equipment outside these
limits will increase the risk from hazards noted
below and may lead to premature and
hazardous pump failure.
1.8
Clear and easy access to all controls, gauges
and dials etc. MUST be maintained at all
times. Hazardous or flammable materials
must NOT be stored in pump rooms unless
safe areas or racking and suitable containers
have been provided.
1.9
IMPROPER INSTALLATION, OPERATION
OR MAINTENANCE OF THIS SPP PUMPS
LTD PRODUCT COULD RESULT IN INJURY
OR DEATH.
1.10 Within the manual, safety instructions are
marked with safety symbols.
Hazard
This symbol refers to general
mechanical aspects of safety.
Hazard
This symbol refers to electrical
safety.
This
symbol
gives
warning of a hazard to the
pump itself, which in turn, could cause a risk
to personal safety.
2. Transport Handling and Storage
Instructions
2.1
Transport
Instream
pumps
are
despatched
fully
assembled. Pumps are protected against
corrosion and packed for transport by normal
road, rail and sea carriers.
2.2
Handling
Crushing Hazard
When lifting the pump unit, use
lifting equipment having a safe
working load rating suitable for the weight
specified. Use suitable slings for lifting any
pump not provided with lifting points.
The use of suitable forklift truck and four-chain
crane sling equipment is recommended but
locally approved equipment of suitable rating
maybe used.
Pumps are usually supplied on pallets for
handling by forklift truck, to lift from the pallet
the pump should be slung as shown.
Pump weight is shown on the Pump general
arrangement drawing.
2.3
Storage
2.3.1 Temporary Storage for up to Six Weeks
If the pump is not to be used immediately, it
should be stored carefully in a horizontal
position, in a sheltered, dry location. Additional
rust preventative should be applied to all
unpainted carbon steel or cast iron parts, and
should not be removed until final installation.
2.3.2 Long Term Storage
Shearing Hazard
Do NOT place fingers or hands etc.
into the suction or discharge pipe
outlets and do NOT touch the
impeller, if rotated this may cause severe
injury. To prevent ingress of any objects,
retain the protection covers or packaging in
place
until
removal
is
necessary
for
installation. If the packaging or suction and
discharge covers are removed for inspection
purposes, replace afterwards to protect the
pump and maintain safety.
For special protection of electric motors, refer
to the manufacturers' instructions. in the
Appendix l.
2.3.3 Exposed or Extreme Conditions Storage
For exposed storage or extreme variants in
atmospheric or environmental conditions,
please refer to SPP Pumps Ltd. for special
storage instructions to suit the conditions
applicable.
ATTENTION