9.2 Standard Metric Nut and Bolt Torque Recommendations
This information is for reference only. The user must check that the torque figures listed here are applicable to the
fasteners used. Nuts and bolts should be neither under nor over tightened.
Grade of Bolt
Approximate Torque (Nm) for Bolt Diameters:
M5
M6
M8
M10
M12
M16
M20
M24
M30
M36
4.6
2.7
4.5
11
22
38
95
185
320
633
1110
8.8
6.9
11.7
28
56
98
244
476
822
1634
2855
10.9
9.4
15.9
38
77
134
332
646
1120
2223
3885
12.9
11.2
19.1
46.4
92
160
397
775
1342
2666
4660
Note: These torque figures are approximate, and for un-plated fasteners only. No allowance has been made for
special finishes or lubricants, washers or mating surfaces.
Bolt and Nut Grade Combinations
Grade of BOLT
4.6
8.8
10.9
12.9
Note: It is permissible to fit higher grade
nuts than recommended.
Grade of NUT
4
8
12
12
Grade Identification
BOLTS & NUTS - Grade 4.6
BS4190 (ISO272, 885, 888 & 4759/1). Grade marking is optional.
Normally there will be no mark other than the 'M' thus:
BOLTS - Grade 8.8
BS 3692 (ISO272, 4759/1). Grade
marking is mandatory, may also
have trade marks
NUTS - Grade 8
Indented marks as a clock face,
dot at 12.00, bar at 8.00,
indicates grade 8 nut.
High Strength Friction Grip Bolts & Nuts
BOLT
NUT
BOLT
Grade10.9
NUT
Grade 12
Maintenance Record
Date
Summary of maintenance & repairs done - replacement parts fitted etc:
Installed & Commissioned
First Oil Change (after 200 hours running)