beautypg.com

Fault finding guide – SPP Pumps Auto Prime Medium Head Open Set - AC & AL Range User Manual

Page 15

background image

Operators Handbook for

Diesel Driven Pump Sets

Manual No/Rev

W72-002E / 11

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time

Page 15 of

16

8. FAULT FINDING GUIDE

Disconnect suction hose

Blank off suction entry

Fit vacuum gauge

Pump Fails to Prime

Reading
between

85 - 89 .5 kpa

(28.5 0 30 ft H20)?

Are

all plugs

tight?

Lift< or =

6.1m (20ft) for AC50/75

8.53m (28ft) for AC80/100

9.75m (32ft) for others?

Type of

unit?

Check vertical

suction lift

Are hoses

leaking, collapsed

or blocked?

Is intake

blocked?

Rectify

Test the Vacuum

Pump directly

Fit Vacuum Gauge

Reading
between

85 - 89 .5 kpa

(28.5 0 30 ft H20)?

NO

YES

Move

Pump

NO

Rectify

NO

NO

Is impeller

blocked?

Rectify

Rectify

Rectify

YES

YES

YES

YES

YES

NO

AC

50/75

Is the

mini ball valve

open?

NO

YES

YES

Rectify

NO

Is reflux

ball seating

properly?

Is oil level

correct?

NO

Is belt drive

tension OK?

YES

Rectify

NO

Rectify

NO

YES

Excessive wear.

Remove pump &

either overhaul or fit

new or exchange

Vacuum Pump

YES

Rectify

NO

Is vacuum

pressure seal

leaking?

YES

Rectify

OTHERS

Is the

pump or NRV

blocked or
damaged?

YES

NO

Rectify

NO

Are all

joints sound &

leak free?

YES

Rectify

NO

Is float

gear free and

intact?

YES

Is pump

casing free from

holes?

Check impeller wear

plate clearances

and rectify

NO

Rectify

YES

Is Vacuum
Pump filter

blocked?

YES

NO

Rectify