60PTVLVA.PCX
Figure 0-10 25 & 60cfm main valve assembly
7.12 SURGE CONTROL VALVE
On 25 and 60cfm priming tanks a
surge control valve is fitted. This
should be checked regularly for signs
of wear or damage. Components
arrowed in Figure 7-11 are vulnerable
to wear and should be replaced if worn
excessively. The valve seat should be
greased to prevent seizure.