again for the presence of starch and glucose on both sides of the membrane. Students should observe the pres-
ence of glucose on both sides of the membrane because glucose is small enough to cross the membrane.
Starch is too large to cross the membrane, so students should not observe starch on both sides of the mem-
brane.

Part two: Measure the effects of varying the sucrose concentrations on the pressure in the columns. Create a
variety of sucrose solutions (0.2 M, 0.4 M, 0.6 M, 0.8 M and 1.0 M). Assign one solution to each group.
Instruct students to place the sucrose solution in one column and distilled water in the other. Students should
measure the pressure and volume within the columns for 24 hours. After 24 hours, students should share their
data with all groups and compare the rate of pressure change related to the varying sucrose concentrations.

*AP® is a registered trademark of the College Board, which was not involved in the production of, and does not endorse this product.

Technical Support

For assistance with any PASCO product, contact PASCO at:

For more information about the Diffusion-Osmosis Apparatus and the latest revision of this Instruction Manual, visit:

www.pasco.com/go?ME-6940

Limited Warranty

For a description of the product warranty, see the PASCO catalog.

Copyright

The PASCO scientific 012-10962A Diffusion-Osmosis Apparatus Instruction Manual is copyrighted with all rights

reserved. Permission is granted to non-profit educational institutions for reproduction of any part of this manual, providing the repro-
ductions are used only in their laboratories and classrooms, and are not sold for profit. Reproduction under any other circumstances,
without the written consent of PASCO scientific, is prohibited.
Trademarks

PASCO and PASCO scientific are trademarks or registered trademarks of PASCO scientific, in the United States

and/or in other countries. AP® is a registered trademark of the College Board, which was not involved in the production of, and does
not endorse this product. All other brands, products, or service names are or may be trademarks or service marks of, and are used to
identify, products or services of their respective owners. For more information visit www.pasco.com/legal.

Patents Pending

The following PASCO products have Patents Pending:

Replacement Parts

Address:

PASCO scientific
10101 Foothills Blvd.
Roseville, CA 95747-7100

Phone:

916-786-3800 (worldwide)
800-772-8700 (U.S.)

Fax:

(916) 786-7565

Web:

www.pasco.com

Email:

[email protected]

ME-6990 Truss Set

PS-2198 Load Cell Amplifier

ME-6991 Bridge Set

PS-2199 Load Cell and Amplifier Set

ME-6992 Advanced Structures Set PS-2200 100 N Load Cell

ME-6995 Road Bed Spares

ME-6940 Diffusion-Osmosis Apparatus

Item

Model

Sensor Mounting Stud

648-08372

Bolt

648-10839