5 installing the transmitter, 1 integral mount, 2 remote mount – Orion Instruments Eclipse 705 User Manual
Page 16
16
57-600 Eclipse
®
Guided Wave Radar Transmitter
2.4.5 Installing the Transmitter
The transmitter can be ordered for installation as an
Integral or Remote configuration.
2.4.5.1 Integral Mount
Remove the protective plastic cap from the top of the
probe. Store the cap in a safe place in case the transmitter
has to be removed later.
Place the transmitter on the probe. Be careful not to bend
probe. Do not allow the gold, high frequency (male) con-
nector to get dirty.
Align the universal connection at the base of the transmitter
housing with the top of the probe. Hand-tighten the
connection.
Rotate the transmitter to face the most convenient direction
for wiring, configuration, and viewing.
When the transmitter is facing the desired direction, use a
1
1
⁄
2
" (38 mm) wrench to tighten the universal connection on
the transmitter to 45 ft-lbs. A torque wrench is highly rec-
ommended. This is a critical connection. DO NOT LEAVE
HAND-TIGHT.
2.4.5.2 Remote Mount
Mount the transmitter/remote bracket as an assembly within
33" or 144" (84 or 366 cm) of the probe. DO NOT
REMOVE TRANSMITTER FROM BRACKET.
Remove the protective plastic cap from the top of the
probe. Store the cap in a safe place in case the transmitter
has to be removed later.
Align the universal connection at the end of the remote
assembly with the top of the probe. Using a 1
1
⁄
2
" (38 mm)
wrench, tighten the universal connection on the transmitter
to 45 ft-lbs. A torque wrench is highly recommended. This is
a critical connection. DO NOT LEAVE HAND-TIGHT.
NOTE: Remote mounting is recommended for all cast 316 SS
enclosures due to their extra weight.