beautypg.com

Simplified system hookup diagram, Transmitter hookup diagram, Transmitter-end installation et1500u units – Nitek ER16500U User Manual

Page 6: Ip camera cable from head-end, Link port network port

background image

Simplified System Hookup Diagram

Link Cable

Up to 2000 feet /

Transmitter-end Installation
ET1500U Units


At the camera location securely mount the transmitter.

Find the Link cable from the head-end and make sure it is properly terminated. Connect Link cable to the “Link Port”
of the transmitter. If the head-end unit is powered up it will sense the connection to the transmitter and turn on the
power. This will be indicated by the green POWER LED on the “Network Port”. After about 15 to 30 seconds the
orange 10/100Mb LED on the “Link Port” will turn-on to tell you that the system is connected. An Ethernet device
does not need to be connected for the transmitter to communicate with the head-end.

Finally, connect an Ethernet device to the transmitters “Network Port”. If the device requires PoE power, the POE
OUT, green LED on the “Link Port” will turn on followed by the LINK STATUS LED on the “Network Port”. The IP
camera or other Ethernet device should now be ready to operate. Continue installing the remaining transmitters as
needed.

IP Camera

Cable from

Head-end

Transmitter Hookup Diagram

Link Port

Network Port

LED INDICATORS

Connect-

or

LED

OFF

ON

FLASHING

Network

Port

Power

No power

Power

Good

Link

Status

No Ether-

net

Link

Ethernet Link

Good

Link
Port

PoE Out

No PoE

Power Out

PoE Power

Good

10/100

No Link

100Mb

10Mb