Device mounting options – Nitek ER16500U User Manual
Page 4
Parts of the ER16500U (Rear Panel)
IEC380 power connector -
115 VAC/240VAC 50/60HZ
Front
Back
Rack Mounting
Device Mounting Options
Wall Mounting
Front
Back
The ER16500U can be rack mounted, wall mounted or used as desk top unit. Use the included mounting ears in the
front or back of the unit depending on your needs. The mounting ears can also be turned to the bottom of the unit
for wall mounting if needed. When mounting the unit, be sure to follow these guide lines.
a. Operating Ambient - Do not install the unit in an assembly where the ambient temperature could exceed
52°C (125°F). NOTE: the ambient temperature in a closed or multi-unit rack assembly could greatly exceed
the ambient temperature outside that assembly.
b. Air-Flow – Leave space on the sides of the unit for airflow into the cooling fans and some space on top of the
unit for air to exit the unit. Adequate air flow is required for safe operation.
c. Mechanical Loading – The mounting ears were designed for two ears to support one unit. Other
configurations, such as mounting other equipment directly on top of the unit or using only one mounting ear,
could cause a hazardous condition due to uneven or excessive mechanical loading.