Faults

7

Faults

Faults

Possible cause

Solution

Control unit

does not run although the
mains cable is connected

Control unit is switched off

X

Switch control unit on, see Chapter 4.

Mains cable is defective

X

Replace the mains cable.

No voltage at the power supply (build-
ing site)

X

Check the power supply.

Power supply phases incorrectly
connected

X

Check the power supply.

Phase missing

See the chapter 5 entitled «Reacting to displays».

The control unit starts and
then cuts out again

Building site power supply cut-off unit
trips

X

Check and if necessary adapt the cut-off protection.

X

If necessary change the power supply.

X

See chapter entitled «Reacting to displays».

No power, even though
the control unit

is running

Incorrect voltage
Defective main motor

X

Make sure that the control unit voltage and frequency
match the mains supply specifications.

X

Contact TYROLIT Hydrostress AG customer service.

The control unit

suddenly cuts out

Over or under voltage

X

Check the power supply. Refer to fault indicator.

Cross section of power supply cable too
small

X

Check the power supply.

Defective plug connection

X

Check the plug connection.

X

Check the power supply.

Group alarm

X

Refer to fault indicator

Main motor is not running

• Main motor potentiometer is in

0-position

• Defective main motor On / Off switch

on remote controller

The remote controller 'ready to operate'
light does not come on.

X

Contact TYROLIT Hydrostress AG customer service.

X

Do not start control unit, see Chapter 4.2

EMERGENCY STOP activated

X

Deactivate EMERGENCY STOP, see Chapter 4.10.

Overheating

X

Check the water circuit and the plug-in couplings.

X

Refer to fault indicator.

No water

X

Switch on the water supply.

X

Refer to fault indicator.

Remote controller
not working

Rechargeable battery or battery have
too little
charge

X

Replace rechargeable battery and recharge or install
cable operation.

X

Replace batteries.

Feed potentiometer indi-
cates no function

• Defective potentiometer in the remote

controller

• Feed motors not connected
• Defective feed motor
• Joystick is in the zero position

X

Contact TYROLIT Hydrostress AG customer service.

X

See Chapter 3.1 / 4.6 / 4.7

Feed motor fails to
build up power

Remote controller potentiometer is de-
fective or in the 0-position

X

Contact TYROLIT Hydrostress AG customer service.

X

See Chapter 4.7.1

Defective cable

X

Contact TYROLIT Hydrostress AG customer service.

Motor fault

X

Contact TYROLIT Hydrostress AG customer service.